Related Experiment Video
Updated: Mar 8, 2026

Studying Left Ventricular Reverse Remodeling by Aortic Debanding in Rodents
Published on: July 14, 2021
Reverse electrical remodeling following pressure unloading in a rat model of hypertension-induced left ventricular
Mihály Ruppert1,2, Sevil Korkmaz-Icöz1, Shiliang Li1
1Department of Cardiac Surgery, University of Heidelberg, Heidelberg, Germany.
Abstract:
Pressure overload-induced left ventricular myocardial hypertrophy (LVH) is characterized by increased proarrhythmic vulnerability. In contrast, pressure unloading leads to reverse remodeling and decreases LVH-associated arrhythmogenicity. However, cellular changes that occur during reverse electrical remodeling have been studied less. Therefore, we aimed to provide an electrocardiographic characterization of a rat model of LVH that underwent pressure unloading and to simultaneously identify the underlying cellular and functional alterations. LVH was induced in rats by abdominal aortic banding for 6 or 12 weeks. Sham-operated animals served as controls. Pressure unloading was evoked by removing the aortic constriction after week 6 (debanded). Serial echocardiography and electrocardiography were performed to investigate the development and the regression of LVH. Protein expression levels were detected by western blot. Myocardial fibrosis was assessed by Picrosirius red staining. Pressure unloading resulted in the regression of LVH in correlation with the reversion of the prolonged corrected QT interval (cQT: 68.7±1.6 vs. 91.0±1.9 ms debanded week 12 vs. AB week 12, P<0.05). Furthermore, pressure unloading prevented the functional decompensation of LVH and simultaneously preserved adequate atrioventricular conduction (PQ: 47.5±1.2 vs. 53.8±1.9 ms debanded week 12 vs. AB week 12, P<0.05). Finally, pressure unloading effectively preceded the broadening of the QRS complex (QRS: 21.8±0.5 vs. 24.9±0.7 ms debanded week 12 vs. AB week 12, P<0.05) in parallel with the attenuation of interstitial collagen accumulation. The regression of LVH with maintained cardiac function and decreased myocardial fibrosis contributes to pressure unloading-induced reverse electrical remodeling.
More Related Videos
07:13A Rat Model of Pressure Overload Induced Moderate Remodeling and Systolic Dysfunction as Opposed to Overt Systolic Heart Failure
Published on: April 30, 2020
07:41A Model of Reverse Vascular Remodeling in Pulmonary Hypertension Due to Left Heart Disease by Aortic Debanding in Rats
Published on: March 1, 2022