Signal-intensity-ratio MRI accurately estimates hepatic iron load in hemodialysis patients
Related Experiment Video
Updated: Mar 8, 2026

Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
Guy Rostoker1, Mireille Laroudie2, Raphaël Blanc3
1Division of Nephrology and Dialysis (Service Néphrologie et de Dialyse), Ramsay-Générale de Santé, Hôpital Privé Claude Galien, Quincy sous Sénart, France.
Background:
Iron overload, diagnosed by means of magnetic resonance imaging (MRI), is an increasingly recognized disorder in hemodialysis patients. Specific MRI protocols have been shown to provide a reliable estimation of tissue iron content in non-renal patient populations but have not been validated in dialysis patients. Such validation studies require liver biopsy for histological comparison, but this invasive and risky procedure raises ethical concerns, especially regarding frail patients with end-stage renal disease.
Materials And Methods:
We compared in a pilot study Scheuer's histological classification and Deugnier and Turlin's histological classification of iron overload (Perls staining) with signal-intensity-ratio MRI values obtained with the Rennes University algorithm in 11 hemodialysis patients in whom liver biopsy was formally indicated for their medical follow-up.
Results:
For Scheuer's histological classification, the Wilcoxon non-parametric matched-pairs test showed no significant difference in the ranking of iron overload by the two methods eg histology and MRI (sum of ranks = 1.5; p = 1). The MRI and Scheuer's histological classifications were tightly correlated (rho = 0.866, p = 0.0035, Spearman's coefficient), as were the absolute liver iron concentrations (LIC) at MRI (rho = 0.860, p = 0.0013, Spearman's coefficient). The absolute liver iron concentrations at MRI were also highly correlated with Deugnier and Turlin's histological scoring (rho = 0.841, p = 0.0033, Spearman's coefficient).
Conclusions:
This pilot study shows that liver iron determination based on signal-intensity-ratio MRI (Rennes University algorithm) very accurately identifies iron load in hemodialysis patients, by comparison with liver histology.
Insights
Magnetic resonance imaging (MRI) accurately measures iron overload in hemodialysis patients. This non-invasive method correlates well with liver biopsy, avoiding risks for patients with end-stage renal disease.
Area of Science:
- Nephrology
- Radiology
- Hepatology
Background:
- Iron overload is a growing concern in hemodialysis patients.
- MRI protocols for iron estimation are validated in non-renal populations but not in dialysis patients.
- Liver biopsy, the gold standard, poses ethical concerns due to invasiveness in frail ESRD patients.
Purpose of the Study:
- To validate signal-intensity-ratio MRI (Rennes University algorithm) for assessing liver iron concentration in hemodialysis patients.
- To compare MRI-based iron load estimation with histological classifications from liver biopsy.
- To establish a reliable, non-invasive method for diagnosing iron overload in this vulnerable population.
Main Methods:
- A pilot study compared MRI values with two histological classifications (Scheuer's and Deugnier and Turlin's) in 11 hemodialysis patients.
- Patients underwent liver biopsy for medical reasons, allowing direct comparison.
- The Rennes University algorithm was used for signal-intensity-ratio MRI analysis.
Main Results:
- MRI and Scheuer's histological classification showed no significant difference in iron overload ranking (p=1).
- Strong correlations were observed between MRI and Scheuer's classification (rho=0.866, p=0.0035).
- High correlations were also found between MRI liver iron concentrations and Deugnier and Turlin's histological scoring (rho=0.841, p=0.0033).
Conclusions:
- Signal-intensity-ratio MRI, using the Rennes University algorithm, accurately determines liver iron load in hemodialysis patients.
- This non-invasive MRI approach provides a reliable alternative to liver biopsy for iron overload assessment.
- The findings support the use of MRI for diagnosing and monitoring iron overload in hemodialysis patients.
Related Concept Videos
Magnetic Resonance Imaging
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration

