Femoral impaction bone grafting with the Elite Plus stem

D E Robinson1, M B Lee, V A Smith

  • 1Avon Orthopaedic Centre, Southmead Hospital, Westbury-on-Trym, Bristol - UK.

Insights

Impaction grafting using the Elite Plus system for revision hip arthroplasty showed a high failure rate, particularly in patients with significant bone loss. Graft incorporation was limited, with poor bone remodeling observed in this study.

Area of Science:

  • Orthopedic Surgery
  • Biomaterials Science

Background:

  • Revision hip arthroplasty is complex, often requiring bone reconstruction.
  • Impaction grafting with allograft is a technique used to address bone stock defects.
  • The Elite Plus system is one option for femoral stem implantation in revision cases.

Purpose of the Study:

  • To evaluate the outcomes of impaction grafting with the Elite Plus femoral stem.
  • To assess graft incorporation and bone healing after revision hip arthroplasty.
  • To determine the failure rate and complications associated with this technique.

Main Methods:

  • A prospective study of 19 hips undergoing revision hip arthroplasty.
  • Utilized the Elite Plus femoral stem with irradiated allograft for impaction grafting.
  • Patients were followed for an average of 33 months with radiographic and clinical assessments.
  • Bone stock loss was graded using the Endo-Klinik classification.

Main Results:

  • Graft incorporation was observed in 32% of cases.
  • No significant trabecular remodeling or cortical repair was evident radiographically.
  • A high failure rate was noted, with 4 patients requiring revision surgery.
  • Complications were more frequent in patients with Endo-Klinik grade 3 bone loss.

Conclusions:

  • Impaction grafting with the Elite Plus system demonstrated a high failure rate in revision hip arthroplasty.
  • The technique appears less successful in patients with substantial bone stock loss.
  • Further research is needed to improve outcomes for complex revision hip surgeries.

Related Concept Videos