Related Experiment Video
Updated: Mar 8, 2026

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Effects of exposure parameters and slice thickness on detecting clear and unclear mandibular canals using cone beam
Gainer R Jasa1, Mayumi Shimizu2, Kazutoshi Okamura3
11 Oral Radiology Division, University of the Republic, Montevideo, Uruguay.
Objectives:
The purpose of this study was to clarify the effects of exposure parameters and image-processing methods when using CBCT to detect clear and unclear mandibular canals (MCs).
Methods:
24 dry half mandibles were divided into 2 groups with clear and unclear MCs based on a previous CBCT study. Mandibles were scanned using a CBCT system with varying exposure parameters (tube voltages 60 kV, 70 kV and 90 kV; and tube currents 2 mA, 5 mA, 10 mA and 15 mA) to obtain a total of 144 scans. The images were processed with different slice thicknesses using ImageJ software (National Institutes of Health, Bethesda, MD). Five radiologists evaluated the cross-sectional images of the first molar region to detect the MCs. The diagnostic accuracy of varying exposure parameters and image-processing conditions was compared with the area under the curve (Az) in receiver-operating characteristic analysis.
Results:
The Az values for clear MCs were higher than those for unclear MCs (p < 0.0001). With increasing exposure voltages and currents, Az values increased, but no significant differences were found with high voltages and currents in clear MCs (p = 1.0000 and p = 0.9340). The Az values of serial images were higher than those of overlaid images (p < 0.0001), and those for thicker slices were higher than those for thinner slices (p < 0.0001).
Conclusions:
Our findings indicate that detection of unclear MCs requires either higher exposure parameters or processing of the images with thicker slices. To detect clear MCs, lower exposure parameters can be used.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...