Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Comparison of Hemodynamic Performance and Clinical Results with EVAHEART Versus HeartMate II
Yorihiko Matsumoto1, Tomoyuki Fujita, Satsuki Fukushima
1From the Departments of *Cardiovascular Surgery; ‡Transplantation, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan; and †Department of Cardiovascular Surgery, Keio University School of Medicine, Tokyo, Japan.
Abstract:
This study aimed to compare the hemodynamic performance and clinical results of the EVAHEART and HeartMate II left ventricular assist devices (LVADs). From 2007 to 2016, fourteen patients received EVAHEART and 28 received HeartMate II at our center. Early survival, driveline infection, and neurologic events were evaluated. Hemodynamic performance was evaluated with transthoracic echocardiography and right heart catheterization. Mean follow-up was 35.5 ± 14.8 months for EVAHEART and 29.8 ± 6.5 months for HeartMate II. Survival rates were comparable between the two groups. After 24 months, freedom from driveline infection was 28% with EVAHEART, and 85% with HeartMate II; freedom from neurologic events was 21% with EVAHEART, and 89% with HeartMate II. Serum lactate dehydrogenase was significantly lower with EVAHEART. There was a significantly greater decrease in left ventricular size with HeartMate II. In catheter examination performed 1 month postoperatively, HeartMate II recipients had significantly lower pulmonary capillary wedge pressure and mean pulmonary pressure, despite a comparable cardiac index. Both devices provided excellent clinical results and hemodynamic performance. HeartMate II could be a better choice to avoid driveline infection and neurologic events. Our results suggest that HeartMate II reduced right ventricular afterload. However, further analysis of more cases is required.
Related Concept Videos
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Heart Failure II: Pathophysiology
Heart Failure IV: Classification and Diagnostic Evaluation
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Catheterization II: Right Heart Catheterization
Cardiopulmonary Resuscitation III: AED Use