Related Experiment Video
Updated: Mar 8, 2026

Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Impact of Mandibular Advancement Therapy on Endothelial Function in Severe Obstructive Sleep Apnea
Frédéric Gagnadoux1,2, Jean-Louis Pépin3,4, Bruno Vielle5
11 Université Bretagne Loire, INSERM UMR 1063, Angers, France.
Rationale:
Endothelial dysfunction, a major predictor of late cardiovascular events, is linked to the severity of obstructive sleep apnea (OSA).
Objectives:
To determine whether treatment with mandibular advancement device, the main alternative to continuous positive airway pressure, improves endothelial function in patients with severe OSA.
Methods:
In this trial, we randomized patients with severe OSA and no overt cardiovascular disease to receive 2 months of treatment with either effective mandibular advancement device or a sham device. The primary outcome, change in reactive hyperemia index, a validated measurement of endothelial function, was assessed on an intention-to-treat basis. An embedded microsensor objectively measured treatment compliance.
Measurements And Main Results:
A total of 150 patients (86% males; mean [SD] age, 54 [10] yr; median [interquartile range] apnea-hypopnea index, 41 [35-53]; mean [SD] Epworth sleepiness scale, 9.3 [4.2]) were randomized to effective mandibular advancement device (n = 75) or sham device (n = 75). On intention-to-treat analysis, effective mandibular advancement device therapy was not associated with improvement of endothelial function compared with the sham device. Office and ambulatory blood pressure outcomes did not differ between the two groups. Effective mandibular advancement device therapy was associated with significant improvements in apnea-hypopnea index (P < 0.001); microarousal index (P = 0.008); and symptoms of snoring, fatigue, and sleepiness (P < 0.001). Mean (SD) objective compliance was 6.6 (1.4) h/night with the effective mandibular advancement device versus 5.6 (2.3) h/night with the sham device (P = 0.006).
Conclusions:
In moderately sleepy patients with severe OSA, mandibular advancement therapy reduced OSA severity and related symptoms but had no effect on endothelial function and blood pressure despite high treatment compliance. Clinical trial registered with www.clinicaltrials.gov (NCT 01426607).
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Treatment for Pulmonary Arterial Hypertension: Endothelin Receptor Antagonists
ETs are synthesized through a complex sequence of enzymatic steps, primarily involving an enzyme referred to as endothelin-converting enzyme...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...