Related Experiment Video
Updated: Mar 8, 2026

Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Optimal diagnostic thresholds for diagnosis of orthostatic hypotension with a 'sit-to-stand test'
Brett H Shaw1, Emily M Garland, Bonnie K Black
1aDepartment of Cardiac Sciences, Libin Cardiovascular Institute of Alberta, University of Calgary, Calgary, Alberta, Canada bAutonomic Dysfunction Center, Division of Clinical Pharmacology cDepartment of Medicine dDepartment of Biomedical Engineering eDepartment of Biostatistics fDepartment of Pharmacology gDepartment of Neurology, Vanderbilt University, Nashville, Tennessee, USA.
Objective:
This study aimed to identify optimal blood pressure cut-offs to diagnose orthostatic hypotension during a sit-to-stand manoeuvre.
Methods:
This was a cross-sectional study of patients and healthy controls from the Vanderbilt Autonomic Dysfunction Center. Blood pressure was measured while supine, seated and standing. Blood pressure changes were calculated from supine-to-standing and seated-to-standing. Orthostatic hypotension was diagnosed on the basis of a supine-to-standing SBP drop at least 20 mmHg or a DBP drop at least 10 mmHg. Receiver operator characteristic (ROC) curves identified optimal sit-to-stand cut-offs.
Results:
Amongst the 831 individuals, more had systolic orthostatic hypotension [n = 354 (43%)] than diastolic orthostatic hypotension [n = 305 (37%)] during lying-to-standing. The ROC curves had good characteristics [SBP area under curve = 0.916 (95% confidence interval: 0.896-0.936), P < 0.001; DBP area under curve = 0.930 (95% confidence interval: 0.909-0.950), P < 0.001]. A sit-to stand SBP drop at least 15 mmHg had optimal test characteristics (sensitivity = 80.2%; specificity = 88.9%; positive predictive value = 84.2%; negative predictive value = 85.8%), as did a DBP drop at least 7 mmHg (sensitivity = 87.2%; specificity = 87.2%; positive predictive value = 80.1%; negative predictive value = 92.0%).
Conclusions:
A sit-to-stand manoeuvre with lower diagnostic cut-offs for orthostatic hypotension provides a simple screening test for orthostatic hypotension in situations wherein a supine-to-standing manoeuvre cannot be easily performed. Our analysis suggests that a SBP drop at least 15 mmHg or a DBP drop at least 7 mmHg best optimizes sensitivity and specificity of this sit-to-stand test.
More Related Videos
08:24Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb
Published on: August 30, 2016
14:52Computerized Dynamic Posturography for Postural Control Assessment in Patients with Intermittent Claudication
Published on: December 11, 2013
Related Concept Videos
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.