Construct failure after open reduction and plate fixation of displaced midshaft clavicular fractures
M A Meeuwis1, A F Pull Ter Gunne1, M H J Verhofstad2
1Dept. of Surgery, St. Elisabeth Hospital, P.O. Box 90151, 5000 LC, Tilburg, The Netherlands.
Introduction:
Worldwide, implants mostly used for fixation of displaced midshaft clavicular fractures (DMCF) are the easily to bend reconstruction plate and the stiffer small fragment locking compression plate. Construct failure rates after plate fixation of DMCF are reported around 5 percent. Possible risk factors for construct failure are implant type and fracture type. However, little is known about the influence of fracture fixation method on construct failure. The aim of this study was to assess construct failure in plate fixation of DMCF and to identify possible risk factors.
Methods:
All consecutive patients treated in a level 1 trauma centre with open reduction and fixation of DMCF using a 3.5-mm reconstruction plate or 3.5-mm small fragment locking compression plate between 2007 and 2015 were evaluated. Potential risk factors for construct failure were analysed using univariate analysis.
Results:
Two hundred and fifty-nine patients were analysed. Fifty DMCF (19%) were fixated with a reconstruction plate and 209 (81%) with a small fragment locking compression plate. Construct failure was seen in 18 patients (6.9%), including 5 broken plates and 13 with screw loosening. Eight percent of all reconstruction plates broke in contrast to 0.5 percent of all small fragment locking compression plates (p=0.001). All broken implants were used as a bridging plate. Loosening of screws was seen in older patients and when the plate was fixated with less than three bicortical screws on one side of the fracture (p=0.002).
Conclusions:
Overall construct failure after open reduction and plate fixation of DMCF occurred in 6.9 percent. Risk factors for plate breakage were the use of a reconstruction plate and a bridging method for fracture fixation. Risk factors for screw loosening were an increasing patient age and plate fixation with less than three bicortical screws on one side of the fracture.
Recommendations:
Based on the results of this study our recommendation is to use a small fragment locking compression plate for open reduction and internal fixation of DMCF. The surgeon should always strive to fixate the plate on both sides of the fracture with at least three bicortical screws.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Flail Chest-I
Flail chest is a severe and potentially life-threatening condition characterized by the fracture of three or more adjacent ribs in multiple places. It is most commonly caused by direct impacts and trauma, such as motor vehicle accidents or injuries from a steering wheel impact. It can also occur due to falls in elderly individuals with osteoporosis, or assaults involving sharp objects.
Pathophysiology
The pathophysiology of flail chest is complex, involving fractures of...