Related Experiment Video
Updated: Mar 8, 2026

08:13
Standardized Method for High-throughput Sterilization of Arabidopsis Seeds
Published on: October 17, 2017
30.8K
Gas versus Steam Sterilization: When to Use Which
Leslie Rendell-Baker1, Robert B Roberts2
1a Department of anesthesiology , Mount Sinai School of Medicine , New York City , USA.
Hospital Topics
|February 1, 2017
Summary
No abstract available in PubMed .
Related Concept Videos
Methods of Sterilization I: Physical Methods
24.7K
As used in a healthcare facility, sterilization destroys all microorganisms through physical or chemical methods. The physical method includes steam, dry heat, boiling water, and radiation.
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
24.7K
Methods of Sterilization II: Chemical Methods
10.2K
In healthcare, the chemical method of sterilization uses chemical sterilants to treat surgical instruments and medical supplies to help prevent the transmission of infectious pathogens to patients. Due to heat sensitivity, most medical supplies and equipment should not be exposed to high temperatures. These parts include rubber, plastic, glass, and other similar elements.
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
10.2K
Physical Methods for Controlling Microbial Growth: Temperature
1.4K
Heat is a widely used method to control microbial growth by targeting and denaturing cellular proteins, thereby killing or inactivating microbes. This method's effectiveness is quantified using parameters such as the thermal death point (TDP), thermal death time (TDT), and decimal reduction time (D value). TDP represents the lowest temperature at which all microorganisms in a liquid suspension are eliminated within 10 minutes, whereas TDT is the time necessary to achieve sterilization at a...
1.4K
Cleaning, Sterilization, and Disinfection
12.3K
Cleaning, disinfection, and sterilization are the methods that help to break the infection chain and prevent disease.
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
12.3K
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
1.4K
Radiation and filtration are essential tools for microbial control, targeting microorganisms through distinct mechanisms. Radiation eliminates microbes by damaging their DNA, either killing them or inhibiting their growth. Based on wavelength, radiation is classified into two types: nonionizing and ionizing radiation.Non-ionizing radiation, such as UV radiation (200–400 nm), is absorbed by DNA, causing defects that effectively disinfect surfaces, air, and water, including safety cabinets.
1.4K
The Joule and Joule–Thomson Experiments
36
Consider an adiabatic system composed of two chambers, A and B, designed such that no heat flows into or out of the system. Initially, chamber A is filled with a gas at a fixed temperature T1, pressure p1, and volume V1, while chamber B is evacuated. The gas is then gradually forced through a rigid, porous barrier to chamber B, ultimately reaching temperature T2, pressure p2, and volume V2. A piston on the right side maintains a constant pressure (p2), which is lower than p1. The significant...
36