Related Experiment Video
Updated: Mar 8, 2026

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
Bailout polytetrafluoroethylene-covered stent implantation for left main bifurcation perforation using the kissing
Noriaki Moriyama1, Yutaka Tanaka1, Shigeru Saito1
1Department of Cardiology and Catheterization Laboratory, Shonan Kamakura General Hospital, Kamakura, Japan.
Abstract:
Coronary artery perforation during percutaneous coronary intervention is a rare, but potentially lethal complication. Immediate balloon expansion at the perforation site can halt the bleeding. Implantation of a coronary polytetrafluoroethylene (PTFE)-covered stent enables the efficient endovascular repair of a coronary artery perforation. However, if the perforation occurs at a bifurcation, a PTFE-covered stent may jail the side branch. We report a difficult case of blowout coronary perforation (Ellis type III) at a left main coronary artery bifurcation, which was successfully sealed with a PTFE-covered stent without interference with the side branch coronary artery circulation. This new strategy might represent a useful salvage option for some patients with a coronary bifurcation perforation. © 2017 Wiley Periodicals, Inc.