Continuous time of flight measurements in a Lissajous configuration

G Dobos1, G Hárs1

  • 1Department of Atomic Physics, Budapest University of Technology and Economics, Budafoki út 8, Budapest H-1111, Hungary.

Related Concept Videos

Couette Flow01:22

Couette Flow

Couette flow represents the flow of fluid between two parallel plates, with one plate fixed and the other moving with a constant velocity. This configuration allows for a simplified analysis using the Navier-Stokes equations, which govern fluid motion under conditions of viscosity and incompressibility. For Couette flow, the assumptions include a steady, laminar, incompressible flow with a zero-pressure gradient in the flow direction. This flow type is beneficial for understanding shear-driven...
1.2K
Steady, Laminar Flow Between Parallel Plates01:17

Steady, Laminar Flow Between Parallel Plates

Understanding steady, laminar flow between parallel plates is essential for analyzing and designing flow in narrow rectangular channels, commonly found in various water conveyance and drainage systems. The Navier-Stokes equations govern fluid motion and are generally challenging to solve due to their nonlinearity. However, simplifications are possible in certain cases, like the steady laminar flow between parallel plates. For this scenario, we assume steady, incompressible, laminar flow.
936
Orthogonal Trajectories01:26

Orthogonal Trajectories

Orthogonal trajectories describe the geometric relationship between two families of curves that intersect each other at right angles. One illustrative case involves a family of parabolas that open sideways along the x-axis. These curves share a common shape but differ by a scaling parameter, resulting in a set of curves that all pass through the origin and widen at different rates.Determining Orthogonal TrajectoriesTo identify the orthogonal trajectories for these parabolas, the first step...
109
Time and frequency -Domain Interpretation of Phase-lag Control01:21

Time and frequency -Domain Interpretation of Phase-lag Control

Phase-lag controllers are widely used in control systems to improve stability and reduce steady-state errors. A dimmer switch controlling the brightness of a light bulb serves as a practical example of phase-lag control, gradually adjusting the bulb's brightness. Mathematically, phase-lag control or low-pass filtering is represented when the factor 'a' is less than 1.
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
430
Relative Velocity in Two Dimensions01:11

Relative Velocity in Two Dimensions

Relative velocity is the velocity of an object as observed from a particular reference frame, or the velocity of one reference frame with respect to another reference frame. The concept of relative velocity can be used to describe motion in two dimensions. Consider a particle P and two reference frames S and S′. The position of the origin of S′ as measured in S is , the position of P as measured in S′ is , and the position of P as measured in S is , which can be evaluated by utilizing...
9.2K
Distance Measurements by Taping01:18

Distance Measurements by Taping

Tapes are essential in surveying for accurate, durable, and short-distance measurements. Made from lightweight, nylon-coated steel, they offer flexibility and strength for rugged outdoor use. The nylon coating protects against rust and wear, extending the tape's life. Standard lengths, around 30 meters, are marked in meters and millimeters for precision.Surveyors select tapes based on site conditions and accuracy needs. Lightweight, nylon-coated tapes are commonly used for ease of handling and...
557