Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Positron Emission Tomography01:29

Positron Emission Tomography

7.9K
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
7.9K
X-ray Imaging01:24

X-ray Imaging

10.9K
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with...
10.9K
Overview of Microscopy Techniques01:22

Overview of Microscopy Techniques

17.4K
The early pioneers of microscopy opened a window into the invisible world of microorganisms. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes that leveraged nonvisible light, such as fluorescence microscopy that uses an ultraviolet light source and electron microscopy that uses short-wavelength electron beams. These advances significantly improved magnification, image resolution, and contrast. By comparison, the...
17.4K
Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

688
Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
688
Computed Tomography01:10

Computed Tomography

9.2K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.2K
Scanning Electron Microscopy01:07

Scanning Electron Microscopy

5.7K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
5.7K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A MAFG~MITF complex drives melanoma phenotype switching and progression.

Nature communications·2026
Same author

Histo-Molecular Intratumoral Heterogeneity in Meningiomas: A Narrative Review.

Cancers·2026
Same author

Integrating Patient-Reported Outcome Measures in Atopic Dermatitis Clinical Practice: An Analysis of the Patient-Oriented Eczema Measure.

Pediatric dermatology·2026
Same author

Good Practice Concepts in Pediatric Critical Care Point-of-Care Ultrasound: A Modified Delphi Consensus Initiative.

Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies·2026
Same author

An AKR1C3-activated kinase inhibitor prodrug.

RSC chemical biology·2026
Same author

Surge in post-streptococcal glomerulonephritis associated with recent rise in group A streptococcal infection.

Archives of disease in childhood·2025

Related Experiment Video

Updated: Mar 8, 2026

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
06:28

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera

Published on: January 30, 2020

13.3K

Inverse-collimated proton radiography for imaging thin materials.

Matthew S Freeman1, Jason Allison1, Malcolm Andrews1

  • 1Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.

The Review of Scientific Instruments
|February 3, 2017
PubMed
Summary
This summary is machine-generated.

Relativistic proton radiography now images extremely thin materials by using an inverse-collimation technique. This advancement expands the technique's sensitivity range to over three orders of magnitude for better material characterization.

More Related Videos

Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
10:18

Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography

Published on: February 21, 2017

8.9K
Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
10:24

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor

Published on: May 7, 2021

2.9K

Related Experiment Videos

Last Updated: Mar 8, 2026

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
06:28

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera

Published on: January 30, 2020

13.3K
Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
10:18

Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography

Published on: February 21, 2017

8.9K
Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
10:24

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor

Published on: May 7, 2021

2.9K

Area of Science:

  • Physics
  • Materials Science
  • Imaging Technology

Background:

  • Relativistic, magnetically focused proton radiography is effective for imaging dense objects (>20 g cm⁻²).
  • Existing methods have limitations in imaging very low areal density materials.

Purpose of the Study:

  • To detail and demonstrate an inverse-collimation scheme for proton radiography.
  • To enhance the sensitivity of proton radiography for imaging thin media (<100 mg cm⁻²).

Main Methods:

  • Utilized the 800 MeV LANSCE proton beam at Los Alamos National Laboratory.
  • Implemented an inverse-collimation scheme at the Fourier plane to remove unscattered protons.
  • Imaged Xenon gas shocked by an aluminum plate at Mach 8.8 using a 5-mrad inverse collimator.
  • Employed Geant4 simulations for proton transport modeling and inverse-collimator design optimization.

Main Results:

  • Achieved high sensitivity to areal densities below 100 mg cm⁻², discerning a 49 mg cm⁻² change across a shock front with a contrast-to-noise ratio of 3.
  • Expanded the sensitive areal density range of proton radiography to approximately 25 mg cm⁻² to 100 g cm⁻² (over three orders of magnitude).
  • Demonstrated the capability to simultaneously image both dense structures and thin ejecta materials.

Conclusions:

  • The inverse-collimation technique significantly enhances proton radiography's sensitivity for thin materials.
  • This method broadens the applicability of proton radiography for characterizing a wider range of areal densities in dynamic experiments.
  • Optimized inverse-collimator design, guided by simulations, is crucial for specific experimental conditions and improved performance with reduced beam emittance.