Related Experiment Video
Updated: Mar 8, 2026

Image Acquisition Method for the Sonographic Assessment of the Inferior Vena Cava
Published on: January 13, 2023
Comparative evaluation of central venous pressure and sonographic inferior vena cava variability in assessing fluid
Manjri Garg1, Jyotsna Sen2, Sandeep Goyal1
1Department of Medicine, Pt. B.D. Sharma University of Health Sciences, Rohtak, Haryana, India.
Objective:
Fluid infusion, the most critical step in the resuscitation of patients with septic shock, needs preferably continuous invasive hemodynamic monitoring. The study was planned to evaluate the efficacy of ultrasonographically measured inferior vena cava collapsibility index (IVC CI) in comparison to central venous pressure (CVP) in predicting fluid responsiveness in septic shock.
Materials And Methods:
Thirty-six patients of septic shock requiring ventilatory support (invasive/noninvasive) were included. Patients with congestive heart failure, raised intra-abdominal pressure, and poor echo window were excluded from the study. They were randomly divided into two groups based on mode of fluid resuscitation - Group I (CVP) and Group II (IVC CI). Primary end-points were mean arterial pressure (MAP) of ≥65 mmHg and CVP >12 mmHg or IVC CI <20% in Groups I and II, respectively. Patients were followed till achievement of end-points or maximum of 6 h. Outcome variables (pulse rate, MAP, urine output, pH, base deficit, and ScvO2 ) were serially measured till the end of the study. Survival at 2 and 4 weeks was used as secondary end-point.
Results:
Primary end-point was reached in 31 patients (15 in Group I and 16 in Group II). Fluid infusion, by either method, had increased CVP and decreased IVC CI with resultant negative correlation between them (Pearson correlation coefficient -0.626). There was no significant difference in the amount of fluid infused and time to reach end-point in two groups. Comparison in outcome variables at baseline and end-point showed no significant difference including mortality.
Conclusion:
CVP and IVC CI are negatively correlated with fluid resuscitation, and both methods can be used for resuscitation, with IVC CI being noninferior to CVP.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...

