Precision of In Vivo Quantitative Tooth Wear Measurement Using Intra-Oral Scans
Published on: July 12, 2022
The relationship between attachment height and attachment area of teeth using a digitizer and a digital computer
Abstract:
Nine lower first bicuspid teeth were mounted in blocks of plastic and their roots were serially sectioned and photographed. Data from the photographs were compiled by a digitizer and a digital computer, which calculated the cumulative root surface area for each millimeter of root height. From these data, three variables, which relate root surface area to root height, were calculated. It was found that if one-half of the height of attachment to the root were lost due to periodontal disease, a mean of 61.5% of the actual attachment area to the root is lost. If a mean of 5.72 mm of root attachment height is lost, or if a mean of 60.6% of the same root height remains, only one-half of the total root attachment area remains to provide tooth support.