Optimizing 2D gas chromatography mass spectrometry for robust tissue, serum and urine metabolite profiling
Zhanru Yu1, Honglei Huang1, Alexander Reim1
1Target Discovery Institute, Nuffield Department of Medicine, University of Oxford, Roosevelt Drive, Oxford OX3 7FZ, UK.
Abstract:
Two-dimensional gas chromatography mass spectrometry (GCxGC-MS) is utilized to an increasing extent in biomedical metabolomics. Here, we established and adapted metabolite extraction and derivatization protocols for cell/tissue biopsy, serum and urine samples according to their individual properties. GCxGC-MS analysis revealed detection of ~600 molecular features from which 165 were characterized representing different classes such as amino acids, fatty acids, lipids, carbohydrates, nucleotides and small polar components of glycolysis and the Krebs cycle using electron impact (EI) spectrum matching and validation using external standard compounds. Advantages of two-dimensional gas chromatography based resolution were demonstrated by optimizing gradient length and separation through modulation between the first and second column, leading to a marked increase in metabolite identification due to improved separation as exemplified for lactate versus pyruvate, talopyranose versus methyl palmitate and inosine versus docosahexaenoic acid. Our results demonstrate that GCxGC-MS represents a robust metabolomics platform for discovery and targeted studies that can be used with samples derived from the clinic.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
High-Resolution Mass Spectrometry (HRMS)