Related Experiment Video
Updated: Mar 8, 2026

Fabrication of Mechanically Tunable and Bioactive Metal Scaffolds for Biomedical Applications
Published on: December 8, 2015
Fabrication and evaluation of bulk nanostructured cobalt intended for dental and orthopedic implants
Fuzeng Ren1, Weiwei Zhu1, Kangjie Chu1
1Department of Materials Science and Engineering, South University of Science and Technology of China, Shenzhen 518055, Guangdong, China.
Abstract:
Bulk nanostructured cobalt (Co) was fabricated by a combination of high energy ball milling and warm pressing. The obtained cobalt has an average grain size of 35nm with measured hardness and elastic modulus of 7.32GPa and 211.4GPa, respectively. Dry sliding wear testing shows such bulk nanostructured Co has high sliding wear resistance. However, electrochemical study shows that such Co has a relatively high corrosion rate and no passive behavior in the artificial saliva solution. X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) analysis further reveal that the corrosion product is composed of insoluble cobalt (II) phosphate and cobalt hydroxide. The evaluation results suggest that bulk nanostructured cobalt can be a promising wear resistant material but may not be suitable for dental/orthopedic implants.