Possibilities and limitations of color quench correction methods for gross alpha/beta measurements
Ivana Stojković1, Branislava Tenjović2, Jovana Nikolov2
1University of Novi Sad, Faculty of Technical Sciences, Novi Sad, Serbia.
Abstract:
Gross alpha/beta activity determination is utilized as a very popular Liquid Scintillation Counting (LSC) technique widely used in routine monitoring of drinking, surface and waste waters. Since quenching phenomena are most problematic effect during LSC measurements, the objectives of this paper are to present, consider and evaluate two methods for color quench correction as a proposal for supplement to the ASTM D 7283-06 method for gross α/β determination. The first method is PSA adjustment: application of previously established dependence of optimal PSA discriminator between alpha and beta events on quench level of sample. The second method assumes counting on usual optimal PSA setting and application of previously determined quench calibration curves in order to correct count rates in alpha and beta channels afterwards. Application on obtained activity results of few artesian well water samples and colored spiked samples, based on the measured SQP(E) value of samples, has been demonstrated, as the opportunity to compare the validity, reliability and limitations of both methods. All samples have been counted on low-background liquid scintilllation counter Quantulus 1220™.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
12:51Simultaneous Multicolor Imaging of Biological Structures with Fluorescence Photoactivation Localization Microscopy
Published on: December 9, 2013
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Emission Spectroscopy: Lab
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...