Related Experiment Video
Updated: Mar 8, 2026

Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
Retention of small molecules on polymethacrylate monolithic capillary columns
Michaela Chocholoušková1, Martina Komendová1, Jiří Urban1
1Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, Pardubice 532 10, Czech Republic.
Abstract:
In this paper, the concentration of N-isopropylacrylamide in the polymerization mixture has been varied to prepare several polymethacrylate monolithic capillary columns. Polymer monoliths combining N-isopropylacrylamide with zwitterion monomer, as well as various dimethacrylate crosslinking monomers have been prepared and characterized. Uracil, thiourea, phenol, toluene, ethylbenzene, propylbenzene, and butylbenzene have been used to characterize retention of prepared capillary columns in the mobile phases with 40-95% of acetonitrile and at working temperatures ranging from 25 to 60°C. By an optimization of six-parameter polynomial models we have found that the retention of small molecules is affected mainly by the concentration of the acetonitrile in the mobile phase with very low contribution of working temperature and combined effect of acetonitrile concentration and temperature. Concentration of the mobile phase controlled also enthalpy of the retention. On the other hand, entropic contribution was almost insensitive to the change of the mobile phase composition, especially for mobile phases containing more than 60% of acetonitrile.
More Related Videos
13:36Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
11:44Cellular Membrane Affinity Chromatography Columns to Identify Specialized Plant Metabolites Interacting with Immobilized Tropomyosin Kinase Receptor B
Published on: January 19, 2022
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Affinity Chromatography
Principles Of Column Chromatography
Analyte Adsorption and Distribution