Related Experiment Video
Updated: Mar 7, 2026

Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025
Peri-implant bleeding on probing: a cross-sectional multilevel analysis of associated factors
Mauro Merli1,2,3, Francesco Bernardelli1, Erica Giulianelli1
1Private practice, Rimini, Italy.
Objectives:
The objective was to evaluate the association between peri-implant bleeding on probing (BoP) and probing depth. Other factors regarding patients, implants, and sites were taken into consideration.
Material And Methods:
Consecutive adult patients with ≥1 dental implant were eligible. Two calibrated operators examined the patients. BoP was the outcome variable. The effects of patient, implant and site factors on BoP were assessed using a 3-level logistic model.
Results:
Fifty-two patients for a total of 92 implants and 552 sites were included in the analysis. The BoP was observed in 217 sites (39%). The odds ratio increased by 1.81 (95% CI from 1.47 to 2.23; P < 0.0001) for each 1 mm increment in probing pocket depth. A significant higher risk was observed also for interproximal vs. approximal surfaces (OR = 1.55; 95% CI from 1.02 to 2.36; P = 0.0402).
Conclusions:
Peri-implant bleeding was associated with site-specific factors.