Related Experiment Video
Updated: Mar 7, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
Improved fat-suppression homogeneity with mDIXON turbo spin echo (TSE) in pediatric spine imaging at 3.0 T
Amber L Pokorney1, Jonathan M Chia2, Cory M Pfeifer1
11 Department of Medical Imaging and Radiology, Phoenix Children's Hospital, Phoenix, AZ, USA.
Abstract:
Background Robust fat suppression remains essential in clinical MRI to improve tissue signal contrast, minimize fat-related artifacts, and enhance image quality. Purpose To compare fat suppression between mDIXON turbo spin echo (TSE) and conventional frequency-selective and inversion-recovery methods in pediatric spine MRI. Material and Methods Images from T1-weighted (T1W) and T2-weighted (T2W) TSE sequences coupled with conventional methods and the mDIXON technique were compared in 36 patients (5.8 ± 5.4 years) at 3.0 T. Images from 42 pairs of T1W (n = 16) and T2W (n = 26) scans were acquired. Two radiologists reviewed the data and rated images using a three-point scale in two categories, including the uniformity of fat suppression and overall diagnostic image quality. The Wilcoxon rank-sum test was used to compare the scores. Results The Cohen's kappa coefficient for inter-rater agreement was 0.69 (95% confidence interval [CI], 0.56-0.83). Images from mDIXON TSE were considered superior in fat suppression ( P < 0.01) in 22 (rater 1) and 25 (rater 2) cases, respectively. In 13 (rater 1) and 11 (rater 2) cases, mDIXON TSE demonstrated improved diagnostic image quality ( P < 0.01). In three cases, fat suppression was superior using inversion-recovery and likewise in one case mDIXON had poorer image diagnostic quality. Lastly, mDIXON and conventional fat-suppression methods performed similarly in 17 (rater 1) and 14 (rater 2) cases, and yielded equal diagnostic image quality in 28 (rater 1) and 30 (rater 2) cases. Conclusion Robust fat suppression can be achieved with mDixon TSE pediatric spine imaging at 3.0 T and should be considered as a permanent replacement of traditional methods, in particular frequency-selective techniques.
Insights
The mDIXON turbo spin echo technique offers superior fat suppression and diagnostic image quality in pediatric spine MRI compared to conventional methods. This advanced technique should replace traditional approaches for better MRI results.
Area of Science:
- Radiology
- Medical Imaging
Background:
- Robust fat suppression is crucial in MRI for enhancing contrast and reducing artifacts.
- Conventional methods include frequency-selective and inversion-recovery techniques.
Purpose of the Study:
- To compare the efficacy of mDIXON turbo spin echo (TSE) versus conventional fat suppression methods in pediatric spine MRI.
- To evaluate fat suppression uniformity and overall diagnostic image quality.
Main Methods:
- A comparative study involving 36 pediatric patients (5.8 ± 5.4 years) at 3.0 Tesla.
- Acquisition of T1-weighted (T1W) and T2-weighted (T2W) TSE images using both mDIXON and conventional techniques.
- Image review by two radiologists assessing fat suppression and diagnostic quality using a three-point scale.
Main Results:
- mDIXON TSE demonstrated significantly superior fat suppression and improved diagnostic image quality compared to conventional methods (P < 0.01).
- Inter-rater agreement for image assessment was good (Cohen's kappa = 0.69).
- Conventional inversion-recovery was superior in a few cases, while mDIXON was poorer in one instance.
Conclusions:
- mDIXON TSE provides robust fat suppression for pediatric spine imaging at 3.0T.
- It is recommended as a replacement for traditional fat suppression techniques, especially frequency-selective methods.
Related Concept Videos
Imaging Studies III: Computed Tomography
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging