Usefulness of measuring acetabular anterior coverage using a tomosynthesis imaging system
Tadahiko Ohtsuru1, Yasuyuki Morita2, Yuhei Horiuchi2
1Department of Orthopaedic Surgery, Tokyo Women's Medical University, Tokyo - Japan.
Tomosynthesis offers a reproducible and versatile method for measuring acetabular anterior coverage, correlating well with false profile radiography. This imaging technique is valuable for detecting developmental dysplasia of the hip joint.
Area of Science:
- Radiology
- Orthopedics
- Medical Imaging
Background:
- Acetabular anterior coverage is crucial for hip joint stability.
- Early detection of hip joint abnormalities is essential for effective treatment.
Purpose of the Study:
- To compare the diagnostic utility of tomosynthesis and false profile (FP) radiography in measuring acetabular anterior coverage.
- To evaluate the reproducibility and effectiveness of tomosynthesis for assessing hip joint morphology.
Main Methods:
- Analyzed 70 hips from patients with early osteoarthritis and 60 hips from healthy volunteers.
- Measured vertical-centre-anterior margin (VCA) angles using both FP radiography (FP-VCA) and tomosynthesis in the sagittal plane (TS-VCA).
- Assessed intraobserver and interobserver reliability for both imaging modalities.
Main Results:
- The TS-VCA angle (median 54.4°) was significantly larger than the FP-VCA angle (median 43.8°).
- Tomosynthesis demonstrated higher reproducibility (intraobserver ICC 0.85, interobserver ICC 0.92) compared to FP radiography (intraobserver ICC 0.68, interobserver ICC 0.79).
- A strong positive correlation was found between TS-VCA and FP-VCA angles, with a regression indicating TS-VCA of 35° corresponding to FP-VCA of 25°.
Conclusions:
- Sagittal plane tomosynthesis is a reliable method for measuring acetabular anterior coverage, correlating well with FP radiography.
- Tomosynthesis offers high reproducibility, simple setup, low radiation dose, and versatility for hip joint imaging.
- A TS-VCA angle cut-off of 35° is effective for detecting developmental dysplasia of the hip.
More Related Videos
09:47Array Tomography Workflow for the Targeted Acquisition of Volume Information using Scanning Electron Microscopy
Published on: July 15, 2021
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Ultrasonography
During an ultrasonography procedure, a handheld device called...