Related Experiment Video
Updated: Mar 7, 2026

Methods for Comparing Nutrients in Beebread Made by Africanized and European Honey Bees and the Effects on Hemolymph Protein Titers
Published on: March 17, 2015
Development of an analytical method for detecting nitrofurans in bee pollen by liquid chromatography-electrospray
Mi Sun Park1, Kyung Tae Kim2, Jong Seong Kang2
1College of Pharmacy Chungnam National University, Daejeon 34134, Republic of Korea; Ministry of Food and Drug Safety Korea, Cheongju-si 28159, Republic of Korea.
Abstract:
Bee pollen collected by honeybees, which is in powdered form, is a good nutritional supplement. Nitrofuran antibiotics are assumed not to be present in bee pollen, which is important as the level of antibiotics in bee pollen is strongly regulated in many countries. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to detect nitrofurans in honey has been developed, but this method is not suitable for bee pollen because of it being in powdered form. During preparation of bee pollen samples, the dispersal of powder particles in an aqueous solution often makes them susceptible to forming an emulsion with solvent components such as hexane and ethyl acetate. This may reduce the reproducibility and sensitivity of analyses of nitrofuran levels in bee pollen. Therefore, we attempted to optimize the sample preparation conditions to detect nitrofurans in bee pollen by determining three nitrofuran residues, namely, 3-amino-2-oxazolidinone (AOZ), 3-amino-5-methyl-morpholino-2-oxazolidinone (AMOZ), and 1-aminohydantoin (AHD), using LC-MS/MS. The optimized method prevented the formation of powder-induced emulsion. To verify the reproducibility and sensitivity of this method, it was validated using nitrofuran-free bee pollen spiked with analytes with different side chains at 1.0, 2.0, and 5.0μgkg-1. The accuracy levels were 94.1%-104.0% and the coefficients of variation were less than 12%. The limits of detection for AOZ, AMOZ, and AHD were 0.18, 0.25, and 0.30μgkg-1, respectively, while their limits of quantitation were 0.59, 0.83, and 1.00μgkg-1. The LC-MS/MS method developed to analyze nitrofuran in bee pollen should contribute to the quality control of bee pollen and food safety.
More Related Videos
07:32Detection of 3-Nitrotyrosine in Atmospheric Environments via a High-performance Liquid Chromatography-electrochemical Detector System
Published on: January 30, 2019
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019