Related Experiment Video
Updated: Mar 7, 2026

Sheathless Capillary Electrophoresis–Mass Spectrometry for Metabolic Profiling of Biological Samples
Published on: October 1, 2016
Conductometric Gradient Ion Exclusion Chromatography for Volatile Fatty Acids
C Phillip Shelor1, Purnendu K Dasgupta1, Hongzhu Liao1
1Department of Chemistry and Biochemistry, University of Texas at Arlington , Arlington, Texas 76019-0065, United States.
Abstract:
We describe a fatty acid vapor extractor (FAVE) as a postcolumn device for sensitive detection following ion exclusion chromatographic (ICE) separation of weak acids. The device consists of a single length of a permselective membrane tube surrounded by a jacket that consists of two isolated sections. The separation column effluent flows through the lumen. A suitable strong acid is put in the upstream, short section of the jacket and permeates in, rendering the lumenal flow strongly acidic (pH ≤ 2) that suppresses eluite weak acid dissociation. A lipophilic polysiloxane membrane is selectively permeable to volatile fatty acids (VFAs). A small fraction of the VFAs transfer to a cocurrent receptor stream of water (or a weak base, e.g., dilute hydroxylamine), flowing through the second, longer section of the jacket. Even though the transferred amount of VFAs may be very small (0.5-5%), significantly better detection limits than conventional suppressed conductometric ICE (SCICE) is possible because of the low and stable background (noise <1 nS/cm). It also permits gradient elution, not possible in SCICE. The polysiloxane based FAVE device is highly selective for VFAs, it shows no response to dicarboxylic acids, hydroxycarboxylic acids, or aromatic acids. As such, trace detection of VFAs in the FAVE extractant is possible while other components can still be monitored conventionally in the FAVE lumenal effluent. Various parameters, related both to device design and operation were studied. The FAVE provides isolation from the eluent matrix and can be used for other detectors where the eluent matrix is incompatible with the detector.
More Related Videos
11:14Fatty Acid 13C Isotopologue Profiling Provides Insight into Trophic Carbon Transfer and Lipid Metabolism of Invertebrate Consumers
Published on: April 17, 2018
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Related Concept Videos
Ion-Exchange Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...