Stability of large maxillary advancements using a combination of prebent and conventional plates for fixation
Marwa Ragaey1, Joseph E Van Sickels2
1Fellow, Division of Oral and Maxillofacial Surgery, University of Kentucky, Chandler Medical Center University of Kentucky, Lexington, Kentucky, USA; ESHA Oral & Cranio-maxillofacial Surgery, Giza, Egypt.
Objective:
The purpose of this study was to determine the stability of one and two jaw maxillary advancements fixed with prebent plates and "L"-shaped plates.
Study Design:
Twenty-six patients met the inclusion criteria (group 1: one jaw [14]; group 2: two jaws [12]). Radiographs were digitized before surgery (T1), immediately after surgery (T2), at 6 weeks (T3), and at 6 months (T4). Stability was assessed comparing A-point movement and change in palatal plane. t tests were used for comparisons between groups, and linear regression analysis was used to assess the stability of A-point T2-T4 versus A-point movement T1-T2 and changes in the palatal plane T1-T2.
Results:
Initial A-point movement between the two groups was significant (group 1 = 7.61 ± 1.73; group 2 = 5.22 ± 1.67) (P = .0002). Both showed relapse (group 1 = 0.78 ± 0.95; group 2 = 0.04 ± 0.49). Although there was no significant relationship between initial A-point movement and relapse, there was a significant negative relationship between change in palatal plane and relapse in group 1. When initial A-point movement and change in palatal plane were combined, as both increased, relapse also increase (P = .007; R2 = 0.41).
Conclusions:
Prebent plates used with "L" plates are a stable fixation technique. Relapse increases with large advancements and change in palatal plane (posterior impaction).
Related Concept Videos
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...
Nuclear Stability
To hold positively charged protons together...
RNA Stability
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Enolate Mechanism Conventions
Stability
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...