Related Experiment Video
Updated: Mar 7, 2026

Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Effects of pressure and frictional heating on protein separation using monolithic columns in reversed-phase
Benjamin F Mann1, Alexey A Makarov1, Heather Wang1
1Merck & Co., Inc., MRL, Department of Process Research & Development, Rahway, NJ 07065, USA.
Abstract:
Pressure is not typically controlled or adjusted independently of flow rate during method development in reversed-phase LC (RPLC). However, it has been shown that pressure has an effect on analyte molecular molar volume, and the magnitude of this effect is greater for proteins and ionizable compounds than neutral small molecules. This phenomenon has received attention recently in the context of porous sub-2-micron particle packed columns. The present study surveys the effect of pressure and frictional heating on RPLC separations using commercially-available monolithic columns at constant flow rate and with controlled external temperature. Because the current monoliths cannot be operated at high pressures, all experiments were conducted with pressures at or below 200bar. Nonetheless, substantial changes in retention were still observed; for example, an increase in pressure of 75bar shifted the retention factor for bovine insulin from 1.27 to 1.78, a 40% increase, while a similar experiment with the neutral small molecule, toluene, showed no change in retention. Results are presented from investigations of model peptides and proteins ranging in size from 1kDa to 30kDa, as well as experiments performed with a silica-based C18 monolith and a polystyrene divinylbenzene monolith functionalized with a phenyl stationary phase. This work indicates that protein separations in monoliths are highly pressure sensitive, and pressure should therefore be considered as an additional parameter in method development for optimizing retention and selectivity. Given these findings, and the ever-increasing importance of chromatographic separations of proteins in both industrial and academic laboratories, improved instrumentation and mechanisms for directly controlling system backpressure could be of great practical value.
Related Concept Videos
Principles Of Column Chromatography
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Elution Process

