Induced p53 loss in mouse luminal cells causes clonal expansion and development of mammary tumours

Luwei Tao1,2, Dongxi Xiang1,2, Ying Xie1,2

  • 1Division of Genetics, Department of Medicine, Brigham and Women's Hospital, Boston, Massachusetts 02115, USA.

Nature Communications
|February 15, 2017
PubMed

Related Concept Videos

T Cell Activation and Clonal Selection01:22

T Cell Activation and Clonal Selection

T cells are integral to our adaptive immune system, recognizing and effectively responding to foreign antigens. T cell activation and clonal selection are pivotal in orchestrating this immune response. This article elucidates these mechanisms, detailing the roles of cluster of differentiation (CD) markers, major histocompatibility complex (MHC) molecules, costimulatory signals, and the process of clonal selection.
Naive T cells that have not yet encountered an antigen express two primary CD...
16.2K
Line Loss01:10

Line Loss

The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
545
The Mammary Glands01:12

The Mammary Glands

The female breast is a hemispheric projection of variable size positioned anterior to the pectoralis major and serratus anterior muscles. A fascia layer composed of dense, irregular connective tissue connects it to these muscles.
Each breast features a pigmented projection known as the nipple, through which milk emerges via closely spaced openings of ducts, referred to as lactiferous ducts. Surrounding the nipple is a circular pigmented area of skin named the areola, which appears rough due to...
2.3K
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
390
Heat and Free Expansion01:24

Heat and Free Expansion

The work done by a thermodynamic system depends not only on the initial and final states but also on the intermediate states—that is, on the path. Like work, when heat is added to a thermodynamic system, it undergoes a change of state, and the state attained depends on the path from the initial state to the final state. Consider an ideal gas cylinder fitted with a piston. When the cylinder is heated at a constant temperature, the gas molecules absorb energy and expand slowly in a...
2.9K
Energy Losses in Transformers01:21

Energy Losses in Transformers

In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality,  the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be  the high resistance of the...
1.3K