Related Experiment Video
Updated: Mar 7, 2026

Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
[Airway management in intensive care units in Rhineland-Palatinate : Evolution over five years]
T Piepho1,2, T Härer3, L Ellermann1
1Klinik für Anästhesiologie, Universitätsmedizin der Johannes Gutenberg-Universität Mainz, Mainz, Deutschland.
Background:
Securing the airway in severely ill patients is associated with a high rate of complications. So far, no information exists about the equipment readily available for airway management in German intensive care units (ICUs). It is also unknown if the range of material has improved over time.
Objectives:
In the present trial the availability of equipment for airway management in ICUs in Rhineland-Palatinate was evaluated at two different times.
Materials And Methods:
Using a structured questionnaire, all ICUs in the state were contacted in the years 2010 and 2015. The availability of different types of equipment for airway management, as well as the presence of a training program for airway management, was evaluated.
Results:
For 2010 data from 64 ICUs were evaluated and for 2015 data sets from 63 ICUs were collected. In 2010 indirect laryngoscopes were available in eight ICUs; in 2015 these devices were directly accessible in 43 units (p < 0.0001). Extraglottic devices were available in all but one ICU in 2010 and all ICUs in 2015. Equipment for emergency surgical airway procedures was available in nearly every ICU (n = 60). The availability of capnography increased significantly from 2010 (n = 12) to 2015 (n = 56; p < 0.0001). In 2010 and 2015, frequent training with a focus on airway management was performed in 23 and 32 units, respectively (p > 0.05).
Conclusion:
Most ICUs in Rhineland-Palatinate have a broad range of equipment for airway management available, and the range has significantly improved over the time period evaluated. The availability of indirect laryngoscopes and capnometers improved significantly. However, it is remarkable that in some ICU's there is still a lack of equipment for advanced airway management.
More Related Videos
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Acute Respiratory Failure-III
Pneumonia V: Nursing management and Prevention
The nurse must practice strict medical asepsis and adhere to infection control guidelines to minimize healthcare-associated infections.
Enhance airway patency
Position the patient correctly to facilitate drainage of the affected lung segments. Manual or mechanical percussion and vibration can also be employed....
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...

