[Comparison of Different Mechanical Insufflator-Exsufflator Systems by Measurement of the Peak Exspiratory Flow
Ansgar Schütz1, Janine Wagner2, Anne Conrad2
1Atemhilfe - Service für außerklinische Beatmung.
Abstract:
Background The management of pulmonary secretion in patients with respiratory muscle weakness using mechanical insufflator-exsufflator systems (MIE) is an established treatment option. There are significant differences in the efficiency of different devices in practical use. The intention of this study was to evaluate the peak exspiratory flow (PEF) values of different devices with and without use of equipment. Methods PEFs of ten MIE were investigated in vitro using different equipment. Results The efficiency of the devices showed significant differences. The use of two bacterial filters showed a significant reduction of 13 % compared to one filter, the use of a catheter mount revealed a significant reduction of 10 %, with an elbow connector additionally 15 %. With a commonly used equipment (1800 mm tube, one filter, catheter tube with elbow) there was a difference of 58 % between the devices Nippy (2,86 l/s) and Pulsar (1,2 l/s). Conclusion There are significant differences in PEF of different MIE and use of different equipment. That could be of therapeutic relevance. Further studies are needed to investigate the clinical relevance of these findings. Recommendations for the use of devices and equipment are necessary to ensure the efficacy of the elimination of pulmonary mucus.
More Related Videos
08:44Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Related Concept Videos
Pipe Flowrate Measurement
The orifice meter is a simple,...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...