The Use of Thermal Infra-Red Imaging to Detect Delayed Onset Muscle Soreness
Published on: January 22, 2012
A Reliability Study Using a Long-Wave Infrared Thermography Device to Identify Relative Tissue Temperature Variations
Diane K Langemo1, James G Spahn
1Diane K. Langemo, PhD, RN, FAAN, is President, Langemo & Associates, and Professor Emeritus, University of North Dakota, Grand Forks, North Dakota. James G. Spahn, MD, FACS, is Founder, Chairman of the Board, and Chief Executive Officer, WoundVision LLC; and Founder, Chairman of the Board, EHOB Inc, Indianapolis, Indiana. Dr Langemo has disclosed that she is a consultant to WoundVision; received payment for manuscript writing from WoundVision; received payment for consulting; and has received grant money from DermaSciences. Dr Spahn has disclosed that he is the managing partner and owner of WoundVision, LLC, and Chief Executive Officer and board member and employee of EHOB, Inc. Submitted November 19, 2015; accepted in revised form April 25, 2016.
Objective:
This study assesses the ability of the Scout (WoundVision LLC, Indianapolis, Indiana), an FDA-approved visual and thermal imaging device and software analysis tool, to provide clinicians with a reliable and reproducible way to incorporate long-wave infrared thermography and relative temperature differential into clinical wound assessment by consistently identifying control areas against which to measure wound temperature.
Methods:
This laboratory-based study utilized 3 adult wound care professionals experienced in control area selection. Twenty-six previously collected wound images were used for the study. The 3 readers placed a control area on each of the 26 wounds 3 different times (n = 78 independent placements) to establish within-reader agreement. To establish between-reader agreement, the readers again placed a control area on each of the 26 wounds (n = 26 independent placements).
Outcome Measures:
This study evaluates 2 aspects of the Scout device's reliability: (1) within- and between-reader agreement of initial patient encounter control area images and (2) between-reader agreement of follow-up encounter control area images.
Results:
The control area measurements were very consistent both within (percent coefficient of variation [%CV] approximately 1%) and between readers (%CV approximately 2%). The average maximum temperature within-reader %CV was 1.14% and the between-reader variation was %CV 1.97%. The average minimum temperature had a within-reader %CV of 1.1% and the between-reader coefficient of variation was 2.01%. The within- and between-reader average difference in mean temperature was 0.14° C and 0.29° C, respectively. The largest mean temperature difference observed within-readers was 0.68° C, and the smallest difference was 0.01° C. The largest difference observed in between-reader mean temperature was 0.96° C, and the smallest was 0.03° C.
Conclusions:
This study demonstrates that clinicians can repeatedly and reliably perform a relative temperature differential analysis using the Scout device to determine an appropriate control area for wound temperature assessment.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...