Related Experiment Video
Updated: Mar 7, 2026

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
MR Imaging in Patients with Cardiac Pacemakers and Implantable Cardioverter Defibrillators
Torsten Sommer1, Wolfgang Bauer2, Katharina Fischbach3
1Klinik für Diagnostische und Interventionelle Radiologie, DRK Krankenhaus Neuwied - Department of Diagnostic and Interventional Radiology, German Red Cross Hospital Neuwied, Germany.
Abstract:
This joint consensus paper of the German Roentgen Society and the German Cardiac Society provides physical and electrophysiological background information and specific recommendations for the procedural management of patients with cardiac pacemakers (PM) and implantable cardioverter defibrillators (ICD) undergoing magnetic resonance (MR) imaging. The paper outlines the responsibilities of radiologists and cardiologists regarding patient education, indications, and monitoring with modification of MR sequences and PM/ICD reprogramming strategies being discussed in particular. The aim is to optimize patient safety and to improve legal clarity in order to facilitate the access of SM/ICD patients to MR imaging. Key Points: · Conventional PM and ICD systems are no longer an absolute but rather a relative contraindication for performing an MR examination. Procedural management includes the assessment of the individual risk/benefit ratio, comprehensive patient informed consent about specific risks and "off label" use, extensive PM/ICD-related and MR-related safety precautions to reduce these risks to the greatest extent possible, as well as adequate monitoring techniques.. · MR conditional pacemaker and ICD systems have been tested and approved for MR examination under specific conditions ("in-label" use). Precise understanding of and compliance with the terms of use for the specific pacemaker system are essential for patient safety.. · The risk for an ICD patient during MR examinations is to be considered significantly higher compared to PM patients due to the higher vulnerability of the structurally damaged myocardium and the higher risk of irreversible damage to conventional ICD systems. The indication for a MR examination of an ICD patient should therefore be determined on a stricter basis and the expected risk/benefit ratio should be critically reviewed.. · This complex subject requires close collaboration between radiology and cardiology.. Citation Format · Sommer T, Bauer W, Fischbach K et al. MR Imaging in Patients with Cardiac Pacemakers and Implantable Cardioverter Defibrillators. Fortschr Röntgenstr 2017; 189: 204 - 217.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies IV: Magnetic Resonance Imaging