Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Using Receiver Operating Characteristic Curves To Optimize Discovery-Based Software with Comprehensive
Brooke C Reaser1, Bob W Wright2, Robert E Synovec1
1Department of Chemistry, University of Washington , Box 351700, Seattle, Washington 98198, United States.
Abstract:
We report a quantitative approach to optimize implementation of discovery-based software for comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC × GC-TOFMS). The software performs a tile-based Fisher ratio (F-ratio) analysis and facilitates a supervised nontargeted analysis based upon the experimental design to aid in the discovery of analytes with statistically different variances between sample classes. The quantitative approach for software optimization uses receiver operating characteristic (ROC) curves. The area under the curve (AUC) for each ROC curve serves as a quantitative metric to optimize two key algorithm parameters: the signal-to-noise ratio (S/N) threshold of the data prior to calculating F-ratios at each m/z mass channel and the number of these F-ratios per m/z used to calculate the average F-ratio of a tile. A total of 25 combinations of S/N threshold by number of m/z were studied. Fifty analytes were spiked into a diesel fuel at two concentration levels to produce two sample classes that should in principle produce 50 positive instances in the ROC curves. The "sweet spot" for F-ratio analysis was determined to be a S/N threshold of 10 coupled with a maximum of the 10 most chemically selective m/z (requiring a minimum of 3 m/z), corresponding to an ∼21% improvement in the discrimination of true positives relative to prior studies. This equates to an additional 9 true positives being discovered at a false positive probability of 0.2 and 5 additional true positives being found overall. Furthermore, optimization of these software parameters did not depend upon a priori determination of the statistically correct number of positive instances in the sample classes. The AUC metric appears to be suitable for the evaluation of all data analysis methods that utilize the proper experimental design.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
High-Performance Liquid Chromatography: Types of Detectors