Related Experiment Video
Updated: Mar 7, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Evaluation of augmented pulse pressure variation using the Valsalva manoeuvre as a predictor of fluid responsiveness
Jeong Jin Min1, Tae Kyong Kim, Jong-Hwan Lee
1From the Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine (JJM, J-HL, JP, HSC), Department of Anesthesiology and Pain Medicine, Seoul National University Hospital (TKK), and Department of Thoracic and Cardiovascular Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea (WSK, YTL).
Background:
Pulse pressure variation (PPV) is a well known dynamic preload indicator of fluid responsiveness. However, its usefulness in open-chest conditions remains controversial.
Objective:
We evaluated whether augmented PPV during a Valsalva manoeuvre can predict fluid responsiveness after sternotomy.
Design:
A prospective, observational study.
Setting:
Single-centre trial, study period from October 2014 to June 2015.
Patients:
Forty-nine adult patients who underwent off-pump coronary arterial bypass grafting.
Intervention:
After midline sternotomy, haemodynamic parameters were measured before and after volume expansion (6 ml kg of crystalloids). PPV was calculated both automatically (PPVauto) and manually (PPVmanual). For PPV augmentation, we performed Valsalva manoeuvres with manual holding of the rebreathing bag and constant airway pressure of 30 cmH2O for 10 s before fluid loading and calculated PPV during the Valsalva manoeuvre (PPVVM).
Main Outcome Measures:
The predictive ability of PPVVM for fluid responsiveness using receiver-operating characteristic curve analysis. Responders were identified when an increase in cardiac index of at least 12% occurred after fluid loading.
Results:
Twenty-one patients were responders and 28 were nonresponders. PPVVM successfully predicted fluid responsiveness with an area under the curve (AUC) of 0.88 [95% confidence interval (95% CI) 0.75 to 0.95; sensitivity 91%, specificity 79%, P < 0.0001] and a threshold value of 55%. Baseline PPVauto and PPVmanual also predicted fluid responsiveness [AUC 0.75 (0.62 to 0.88); sensitivity 79%, specificity 75%; and 0.76 (0.61 to 0.87]; sensitivity 71%, specificity 71%, respectively). However, only PPVVM showed a significant AUC-difference from that of central venous pressure (P = 0.008) and correlated with the change of cardiac index induced by volume expansion (r = 0.6, P < 0.001).
Conclusion:
Augmented PPV using a Valsalva manoeuvre can be used as a clinically reliable predictor of fluid responsiveness under open-chest condition.
Trial Registration:
ClinicalTrials.gov identifier: NCT02457572.
Related Concept Videos
Measurement of Blood Pressure
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)