Related Experiment Video
Updated: Mar 7, 2026

Fetal Echocardiography and Pulsed-wave Doppler Ultrasound in a Rabbit Model of Intrauterine Growth Restriction
Published on: June 29, 2013
The systematic error in the estimation of fetal weight and the underestimation of fetal growth restriction
Justin R Lappen1, Stephen A Myers1
1Division of Maternal Fetal Medicine, MetroHealth Medical Center, Case Western Reserve University School of Medicine, Cleveland, OH.
Insights
Poor diagnosis of fetal growth restriction (FGR) may stem from ultrasound errors. Incorporating systematic error in estimated fetal weight (EFW) ultrasound could improve detection of FGR, reducing perinatal risks.
Area of Science:
- Obstetrics and Gynecology
- Fetal Medicine
- Diagnostic Imaging
Background:
- Fetal growth restriction (FGR) is linked to poor perinatal outcomes and long-term health issues.
- Antenatal diagnosis of FGR is challenging, with most cases undiagnosed.
- Current clinical practice often overlooks systematic errors in ultrasound-based estimated fetal weight (EFW).
Purpose of the Study:
- To highlight the impact of systematic error in ultrasound EFW on FGR underdiagnosis.
- To propose incorporating ultrasound EFW systematic error into FGR screening and surveillance strategies.
- To analyze the effect of EFW error on identifying fetuses at risk for FGR.
Main Methods:
- Development of an analytic model using published data from the Eunice Kennedy Shriver National Institute of Child Health and Human Development Fetal Growth Studies.
- Quantification of the systematic error in ultrasound EFW.
- Evaluation of the impact of this error on FGR underdiagnosis across different risk percentiles (10th, 5th, 3rd).
Main Results:
- Systematic error in ultrasound EFW significantly contributes to the underestimation of fetuses with FGR.
- The magnitude of underdiagnosis is influenced by the chosen percentile for risk assessment.
- Analysis demonstrates a consistent underestimation bias across various risk thresholds.
Conclusions:
- The systematic error in ultrasound EFW is a critical, overlooked factor in FGR underdiagnosis.
- Current paradigms for identifying and managing fetuses at risk for FGR require modification to account for EFW systematic error.
- Integrating this error into clinical recommendations can improve antenatal detection rates and subsequent perinatal outcomes.
Abstract:
Fetal growth restriction (FGR) is associated with an increased risk of perinatal morbidity and mortality and has lifetime implications for the risk of chronic medical conditions. Antenatal diagnosis of FGR remains poor, with the majority of cases remaining undiagnosed. Although several factors contribute to the underdiagnosis of FGR, the error in ultrasound estimation of fetal weight (EFW) generally is not considered in clinical practice. In this commentary, we suggest that the intrinsic, or systematic, error in ultrasound EFW is a significant factor contributing to the underestimation of fetuses predicted to have FGR and should be incorporated into screening and surveillance recommendations. To illustrate this point, we present an analytic model of published data from the Eunice Kennedy Shriver National Institute of Child Health and Human Development Fetal Growth Studies characterizing and quantifying the impact of the systematic error in ultrasound EFW on the underdiagnosis of FGR. Independent of the centile at which the risk of adverse outcome related to FGR begins, whether the 10th, 5th or 3rd percentile, our analysis suggests the need to modify to the current paradigm for identifying and responding to fetuses estimated to be at risk.
Related Concept Videos
Random and Systematic Errors
Regression Toward the Mean
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Uncertainty in Measurement: Accuracy and Precision
Teratogenicity
Errors occurring during blood pressure monitoring
Several factors...