Related Experiment Video
Updated: Mar 7, 2026

Using Flexible Gold-Titanium Reaction Cells to Simulate Pressure-Dependent Microbial Activity in the Context of Subsurface Biomining
Published on: October 5, 2019
A contribution to improve the calculation of the acid generating potential of mining wastes
Aurélie Chopard1, Mostafa Benzaazoua1, Hassan Bouzahzah1
1Research Institute on Mines and Environment (IRME), Université du Québec en Abitibi-Témiscamingue (UQAT), Rouyn-Noranda, QC, Canada.
Abstract:
Mine wastes from sulfide-bearing ore extraction and processing are often stored at the surface of mine sites and could generate mine drainage. Prediction tests are completed to predict the water quality associated with the deposition of mining wastes. Static tests can quickly assess the acid-generating potential (AP) and the neutralization potential (NP). Whereas some studies recommend to take into account a mineral reactivity factor for the NP determination, the reactivity rates of acidifying minerals are not considered in the AP calculation. The aim of this study is to bring contribution to the improvement of the static test determination by adding kinetic factors in the AP determination. Eight sulfides (pyrite, Ni-pyrite, pyrrhotite, Ni-pyrrhotite, chalcopyrite, galena, sphalerite, arsenopyrite) and a sulfosalt (gersdorffite) were separately submitted to kinetic tests in modified weathering cells. This test was selected for its rapidity of results and for the low amount of material used, as it is somewhat difficult to obtain pure minerals samples. Five synthetic tailings were composed by mixing pure sulfides in various proportions and submitted to the same kinetic tests. The oxidation rates of synthetic tailings were compared with the weighted combined oxidation rates of individual pure sulfides. The oxidation rates of the synthetic tailings calculated from those of pure sulfides are within the same order of magnitude than those obtained through the kinetic experiments. The AP of synthetic tailings were calculated according to standard equations of the literature and compared with the new method.
Related Concept Videos
Acid Attack on Concrete
The rate at which hydrogen...
Standard Electrode Potentials
Metabolism of Chemolithotrophs
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Factors Affecting Solubility
Precipitation and Co-precipitation

