Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Microscale Computed Tomography (μCT) Imaging of Leak Pathways for Optimized Leak-Free 3D Printed Fluidics.

ACS applied polymer materials·2025
Same author

Photoredox catalysed reductive cleavage of dibenzothiophene dioxides enabled by a temperature-controlled photoreactor.

Chemical science·2025
Same author

Differential analysis of factors influencing motorcycle single-vehicle crash severity on roadway segments and intersections.

Traffic injury prevention·2025
Same author

Automated Droplet-Based Microfluidic Analyzer for <i>In Situ</i> Monitoring of Ammonium Ions in River Water.

ACS ES&T water·2025
Same author

Exploring the injury severity of unlicensed powered two- and three-wheeler drivers in two-vehicle crashes in China.

Scientific reports·2025
Same author

MXene synthesis in a semi-continuous 3D-printed PVDF flow reactor.

Nanoscale advances·2025
Same journal

Tunable self-assembling cellular microarray for single-neutrophil vital and suicidal extracellular traps.

Lab on a chip·2026
Same journal

Precise programmable tumor cell subpopulation sorting <i>via</i> an electromagnetic microfluidic platform.

Lab on a chip·2026
Same journal

Bridging dimensions: combining one- and two-photon 3D printing for microfluidic device fabrication.

Lab on a chip·2026
Same journal

Microfluidic rare cell analysis beyond counting: workflow design from enrichment to multi-omics.

Lab on a chip·2026
Same journal

A sperm racetrack to separate sperm by swim speed.

Lab on a chip·2026
Same journal

Controlled encapsulation and droplet size prediction in two-step microfluidic double emulsions.

Lab on a chip·2026
See all related articles

Related Experiment Video

Updated: Mar 7, 2026

High Speed Droplet-based Delivery System for Passive Pumping in Microfluidic Devices
10:22

High Speed Droplet-based Delivery System for Passive Pumping in Microfluidic Devices

Published on: September 2, 2009

14.3K

Phased peristaltic micropumping for continuous sampling and hardcoded droplet generation.

Adrian M Nightingale1, Gareth W H Evans1, Peixiang Xu2

  • 1Faculty of Engineering and the Environment, University of Southampton, Southampton, SO17 1BJ UK. x.niu@soton.ac.uk and Institute for Life Sciences, University of Southampton, Southampton, SO17 1BJ UK.

Lab on a Chip
|February 21, 2017
PubMed
Summary
This summary is machine-generated.

This study introduces a novel peristaltic micropump for robust droplet generation in microfluidics. This method enables precise control over droplet composition for chemical analysis, moving beyond lab settings.

More Related Videos

Author Spotlight: Unveiling the Polyfunctionality and Heterogeneity in Immune Responses
09:43

Author Spotlight: Unveiling the Polyfunctionality and Heterogeneity in Immune Responses

Published on: March 8, 2024

2.5K
A Microfluidic Chip for ICPMS Sample Introduction
11:16

A Microfluidic Chip for ICPMS Sample Introduction

Published on: March 5, 2015

11.8K

Related Experiment Videos

Last Updated: Mar 7, 2026

High Speed Droplet-based Delivery System for Passive Pumping in Microfluidic Devices
10:22

High Speed Droplet-based Delivery System for Passive Pumping in Microfluidic Devices

Published on: September 2, 2009

14.3K
Author Spotlight: Unveiling the Polyfunctionality and Heterogeneity in Immune Responses
09:43

Author Spotlight: Unveiling the Polyfunctionality and Heterogeneity in Immune Responses

Published on: March 8, 2024

2.5K
A Microfluidic Chip for ICPMS Sample Introduction
11:16

A Microfluidic Chip for ICPMS Sample Introduction

Published on: March 5, 2015

11.8K

Area of Science:

  • Biochemical analysis
  • Microfluidics engineering

Background:

  • Droplet microfluidics is a key tool for analyzing small sample volumes.
  • Conventional droplet generation methods (T-junction, flow focusing) are sensitive to flow conditions and fluid properties.

Purpose of the Study:

  • To present an alternative, robust method for droplet generation using a peristaltic micropump.
  • To demonstrate controllable droplet dynamics and composition for chemical operations.
  • To enable field-deployable microfluidic applications.

Main Methods:

  • Utilized a peristaltic micropump to deliver aqueous and oil phases in antiphase pulses.
  • Developed a "chopping"-like droplet generation technique.
  • Integrated sample collection and droplet generation near the sampling site.

Main Results:

  • Achieved droplet generation insensitive to liquid properties and flow rates.
  • Demonstrated controllable droplet volumes determined solely by pump design.
  • Enabled hardcoding of droplet sequences for chemical operations like titrations and dilutions.

Conclusions:

  • The peristaltic micropump offers a robust and controllable approach to droplet generation.
  • This method facilitates in situ sampling and chemical measurement.
  • The technology is suitable for field-deployable droplet microfluidics applications.