Related Experiment Video
Updated: Mar 7, 2026

Glaucoma-inducing Procedure in an In Vivo Rat Model and Whole-mount Retina Preparation
Published on: March 12, 2016
The physical properties of generic latanoprost ophthalmic solutions are not identical
Miriam Kolko1,2, Peter Koch Jensen1
1Department of Ophthalmology, Zealand University Hospital, Roskilde, Denmark.
Purpose:
To compare various characteristics of Xalatan® and five generic latanoprost ophthalmic solutions.
Methods:
Drop size, volume, pH values, buffer capacity, viscosity, hardness of bottles and costs were determined. Drop sizes were measured in triplicates by micropipettes, and the number of drops counted in three separate bottles of each generic product was determined. pH values were measured in triplicates by a calibrated pH meter. Buffer capacity was exploited by titrating known quantities of strong base into 2.5 ml of each brand and interpolated to neutral pH. Kinematic viscosity was determined by linear regression of timed gravity flow from a vertical syringe through a 21-G cannula. The hardness of the bottles was evaluated by gradually increasing tension on a hook placed around each bottle until a drop was expelled reading the tension on an attached spring scale.
Results:
Drop sizes and the number of drops in the bottles varied significantly between the generic drugs. The control value of pH in the brand version (Xalatan® ) was markedly lower compared to the generic latanoprost products. Titration of Xalatan® to neutrality required substantially more NaOH compared to the generic latanoprost products. Finally, the viscosity revealed a significant variability between brands. Remarkable differences were found in bottle shapes, bottle hardness and costs of the latanoprost generics.
Conclusion:
Generic latanoprost eye drops should not be considered identical to the original brand version as regards to drop size, volumes, pH values, buffer capacity, viscosity, hardness of bottles and costs. It is likely that these issues affect compliance and intraocular pressure (IOP)-lowering effect. Therefore, re-evaluation of the requirements for introducing generic eye drops seems reasonable.
Related Concept Videos
Ophthalmic Drug Delivery Systems
Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Local Anesthetics: Common Agents and Their Applications
Cocaine is an ester of benzoic acid and methylecgogine. It is used to anesthetize and vasoconstrict locally. Currently, it is used primarily for topical applications. It is beneficial for surgeries on the upper respiratory tract, providing anesthesia and shrinking the mucosa. Cocaine in the form of cocaine hydrochloride is...
Clinically Relevant Drug Product Specifications: Methods of Establishment
Pharmaceutical Alternatives: Polymorphic Form-Related and Particle Size-Related Therapeutic Nonequivalence

