Fabrication and Demonstration of Mercury Disc-Well Probes for Stripping-Based Cyclic Voltammetry Scanning

Zachary J Barton1, Joaquín Rodríguez-López1

  • 1Department of Chemistry, University of Illinois at Urbana-Champaign , 600 South Mathews Avenue, Urbana, Illinois 61801, United States.

Analytical Chemistry
|February 24, 2017
PubMed

Related Concept Videos

Voltammetry: Stripping Methods01:13

Voltammetry: Stripping Methods

Anodic Stripping Voltammetry (ASV), Cathodic Stripping Voltammetry (CSV), and Adsorptive Stripping Voltammetry (AdSV) are electrochemical techniques used to determine trace amounts of analytes in solution. These methods involve applying a potential to an electrode and measuring the resulting current.
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
1.1K
Voltammetric Techniques: Linear-Scan (E vs Time)01:12

Voltammetric Techniques: Linear-Scan (E vs Time)

Polarography is a classical voltammetric technique used to analyze electrochemical reactions. This method applies a linear potential sweep to a dropping mercury electrode (DME), and the resulting current is measured. A dropping mercury electrode is commonly used as the working electrode in polarography. It consists of a capillary tube filled with mercury, where the tiny droplet forms at the tip. This droplet continuously drops from the capillary, creating a new electrode surface for each...
1.4K
Voltammetry: Overview01:20

Voltammetry: Overview

Voltammetry is an electroanalytical technique in which the current flowing through an electrochemical cell is measured as a function of applied potential, typically under conditions of concentration polarization. The technique provides valuable information about redox-active species, and the current response is plotted as a voltammogram.
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
3.2K
Voltammetric Techniques: Cyclic Voltammetry01:10

Voltammetric Techniques: Cyclic Voltammetry

Cyclic voltammetry (CV) is an electrochemical technique used to investigate the redox properties of a chemical species. It involves measuring the current response of an electrochemical cell as a function of the applied potential. The setup for cyclic voltammetry typically consists of a working electrode, a reference electrode, and a counter electrode—all immersed in an electrolyte solution. The working electrode is where the redox reaction of interest occurs, while the reference electrode...
1.8K
Preparation of Samples for Electron Microscopy01:20

Preparation of Samples for Electron Microscopy

To be visualized by an electron microscope, either transmission or scanning, biological samples need to be fixed (stabilized) so the electron beam does not destroy them and dried thoroughly (desiccated/dehydrated) so the vacuum does not affect them. Fixation needs to be done as quickly as possible because the sample properties will start changing as soon as it is removed from its natural environment. For example, in a tissue sample, the oxygen levels begin decreasing, causing an altered...
7.5K
Overview of Microscopy Techniques01:22

Overview of Microscopy Techniques

The early pioneers of microscopy opened a window into the invisible world of microorganisms. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes that leveraged nonvisible light, such as fluorescence microscopy that uses an ultraviolet light source and electron microscopy that uses short-wavelength electron beams. These advances significantly improved magnification, image resolution, and contrast. By comparison, the...
17.4K