Related Experiment Video
Updated: Mar 7, 2026

Measuring the Behavioral Effects of Intraocular Scatter
Published on: February 18, 2021
Effects of Light Scatter and Blur on Low-Contrast Vision and Disk Halo Size
María Cinta Puell1, Catalina Palomo-Álvarez
1*PhD Applied Vision Research Group, Faculty of Optics and Optometry, Universidad Complutense de Madrid, Madrid, Spain (both authors).
Purpose:
To investigate the individual effects of forward light scatter (FLS) and refractive blur on low-contrast vision and the size of the disk halo produced in response to an external glare source.
Methods:
Monocular disk halo radius, high- and low-contrast distance visual acuity (HCVA, LCVA), and contrast sensitivity (CS) were determined in 25 eyes of 25 healthy subjects under normal, FLS, and blur conditions. FLS was induced using the filter Black ProMist 2 to simulate an early cataract. Blur was induced using a +1.00 diopter lens to simulate an uncorrected refractive error.
Results:
Similar significant mean increases in halo radius were observed for the FLS (0.32 ± 0.10 log arc min; P < .0001) and refractive blur (0.40 ± 0.18 log arc min; P < .0001). Under induced blur, 3 lines of HCVA (0.32 ± 0.15 logMAR; P < .0001) and 4 lines of LCVA (0.39 ± 0.16 logMAR; P < .0001) were lost. FLS had a minimal (but significant) effect on HCVA, but worsened mean LCVA by more than 1 line (0.13 ± 0.10 logMAR; P < .0001). Similar significant mean CS reductions of 0.17 ± 0.12 (P < .0001) and 0.14 ± 0.12 log units (P < .0001) were produced in response to FLS and refractive blur, respectively (approximately 1 triplet).
Conclusions:
Forward light scatter and refractive blur contributed to an increased size of the disk halo produced by a glare source in similar proportion. Although defocus blur has a substantial effect on LCVA, a loss of more than 1 line of LCVA after best refractive correction would be indicative of FLS.
More Related Videos
Related Concept Videos
Focusing of Light in the Eye
Photoreceptors and Visual Pathways
Halo Effect
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Confocal Fluorescence Microscopy

