Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
Published on: August 17, 2022
Specific BIVA recognizes variation of body mass and body composition: Two related but different facets of nutritional
Roberto Buffa1, Elena Mereu1, Valeria Succa1
1Department of Life and Environmental Sciences, University of Cagliari, Monserrato (Cagliari), Italy.
Objective:
The aim of this study was to demonstrate the different information provided by body mass index (BMI) in combination with specific bioelectrical impedance vector analysis (specific BIVA) in the measure of relative body fat.
Methods:
Anthropometric and bioelectrical values and dual-energy x-ray absorpitometry measurements from a sample of 1590 US adults of both sexes were retrieved from the National Health and Nutrition Examination Survey 2003-2004. The sample distribution of the BMI of each sex was divided into deciles. Quartiles were calculated for percent fat mass (FM%) after stratifying by BMI deciles. Body composition and bioelectrical characteristics of groups below the first and above the third quartile were compared using analysis of variance and the Hotelling's T-square test.
Results:
BMI and specific BIVA showed a different accuracy in detecting body composition variations: BMI showed similar values in groups represented by different FM percentages, whereas the bioelectrical differences were statistically significant. The mean impedance vectors corresponding to cases below the first FM% quartiles were shorter and located on the left side of the ellipses (the region of higher fat-free mass), whereas those above the third FM% quartiles were on the right and toward the upper pole (the region of higher FM%).
Conclusions:
Specific BIVA is a technique for the evaluation of body composition which can add relevant information regarding BMI.
More Related Videos
04:05Author Spotlight: Unveiling Prognostic Indicators in Heart Failure - The Role of Phase Angle and Bioelectrical Impedance Analysis
Published on: June 30, 2023
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
Related Concept Videos
Bode Plots Construction
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Body Water Content and Fluid Compartments
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...