Related Experiment Video
Updated: Aug 4, 2026

A Low Cost Setup for Behavioral Audiometry in Rodents
Published on: October 16, 2012
Rats concatenate 22 kHz and 50 kHz calls into a single utterance
Christine Hernandez1, Mark Sabin2, Tobias Riede3,2,4
1College of Veterinary Medicine, Midwestern University, 19555 N 59th Ave, Glendale, AZ 85308, USA.
Abstract:
Traditionally, the ultrasonic vocal repertoire of rats is differentiated into 22 kHz and 50 kHz calls, two categories that contain multiple different call types. Although both categories have different functions, they are sometimes produced in the same behavioral context. Here, we investigated the peripheral mechanisms that generate sequences of calls from both categories. Male rats, either sexually experienced or naïve, were exposed to an estrous female. The majority of sexually naïve male rats produced 22 kHz and 50 kHz calls on their first encounter with a female. We recorded subglottal pressure and electromyographic activity of laryngeal muscles and found that male rats sometimes concatenate long 22 kHz calls and 50 kHz trill calls into an utterance produced during a single breath. The qualitatively different laryngeal motor patterns for both call types were produced serially during the same breathing cycle. The finding demonstrates flexibility in the laryngeal-respiratory coordination during ultrasonic vocal production, which has not been previously documented physiologically in non-human mammals. Since only naïve males produced the 22 kHz-trills, it is possible that the production is experience dependent.
Related Concept Videos
Homologous Recombination
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
¹H NMR Signal Multiplicity: Splitting Patterns
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Homologous Recombination
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...

