Related Experiment Video
Updated: Aug 10, 2026

Development of an In Vitro Ocular Platform to Test Contact Lenses
Published on: April 6, 2016
Twelve years continuous wear of the same therapeutic soft contact lens: a case report
S Kokolakis1, S Baltatzis, P Zafirakis
1General Hospital of Athens, University Eye Clinic, Athens Medical School, Athens Greece.
Purpose:
To describe a case of a patient who had worn the same therapeutic soft contact lens (TSCL) continuously for twelve years, since he had failed to attend normal follow-up visits.
Methods:
Microbiological histological and scanning electron microscopic (SEM) studies of conjunctiva, cornea and TSCL were done.
Results:
Cultures were negative. Corneal histology revealed mild stromal edema and mild epithelial parakeratosis. Corneal SEM was remarkable for the preservation to some extent of normal corneal epithelial specialization with microtricae and microvillae. SEM of the TSCL showed a ruffed multi-layer surface with several cracks including different types of cells.
Conclusions:
The patient showed surprising tolerance to the continuous wear of the same contact lens for l2 years. (Eur J Ophthalmol 1999, 9: 312-14).