Related Experiment Video
Updated: Feb 8, 2026

Improved Home Blood Pressure Control by CT-guided Ozone-mediated Renal Denervation for Patients with Resistant Hypertension
Published on: June 6, 2025
High-Pressure Ozone-Induced Dissociation for Lipid Structure Elucidation on Fast Chromatographic Timescales
Berwyck L J Poad1, Martin R Green2, Jayne M Kirk2
1Central Analytical Research Facility, Institute for Future Environments, Queensland University of Technology , Brisbane, Queensland 4001, Australia.
Abstract:
Ozone-induced dissociation (OzID) is a novel ion activation technology that exploits the gas-phase reaction between mass-selected ions and ozone inside a mass spectrometer to assign sites of unsaturation in complex lipids. Since it was first demonstrated [ Thomas et al. Anal. Chem. 2008 , 80 , 303 ], the method has been widely deployed for targeted lipid structure elucidation but its application to high throughput and liquid chromatography-based workflows has been limited due to the relatively slow nature of the requisite ion-molecule reactions that result in long ion-trapping times and consequently low instrument duty cycle. Here, the implementation of OzID in a high-pressure region, the ion-mobility spectrometry cell, of a contemporary quadrupole time-of-flight mass spectrometer is described. In this configuration, a high number density of ozone was achieved and thus abundant and diagnostic OzID product ions could be observed even on the timescale of transmission through the reaction region (ca. 20-200 ms), representing a 50-1000-fold improvement in performance over prior OzID implementations. Collisional activation applied prereaction was found to yield complementary and structurally informative product ions arising from ozone- and collision-induced dissociation. Ultimately, the compatibility of this implementation with contemporary ultrahigh performance liquid chromatography is demonstrated with the resulting hyphenated approach showing the ability to separate and uniquely identify isomeric phosphatidylcholines that differ only in their position(s) of unsaturation.
Related Concept Videos
Structure of Lipids
Structure of Lipids
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
What are Lipids?
Gene Evolution - Fast or Slow?
In contrast, regions which code...
Chromatographic Methods: Terminology