Related Experiment Video
Updated: Mar 6, 2026

Author Spotlight: Microbial Control and Monitoring Strategies for Cleanroom Environments and Cellular Therapies
Published on: March 17, 2023
Evaluation of an ultraviolet room disinfection protocol to decrease nursing home microbial burden, infection and
Christine R Kovach1, Yavuz Taneli2, Tammy Neiman3
1University of Wisconsin-Milwaukee, 1921 East Hartford Avenue, Milwaukee, WI, 5321, USA. ckovach@uwm.edu.
Ultraviolet disinfection significantly reduced microbial counts on surfaces and decreased nursing home acquired infections and hospitalizations. Enhanced environmental surface disinfection in long-term care facilities is recommended to lower infection rates.
Area of Science:
- Infection Control
- Environmental Hygiene
- Public Health
Background:
- Nursing home infection control primarily targets healthcare worker-resident transmission.
- Limited evidence exists on the impact of environmental surface decontamination on infection rates and resident outcomes.
Purpose of the Study:
- To assess if ultraviolet (UV) disinfection impacts microbial counts on high-touch surfaces.
- To determine if UV disinfection is associated with changes in nursing home-acquired infection rates and infection-related hospitalizations.
Main Methods:
- A 160-bed long-term care facility implemented UV light disinfection for resident rooms post-discharge and shared spaces weekly.
- Thirty-six months of pre-intervention data were compared with 12 months of post-intervention data for infections and hospitalizations.
- Microbial and adenosine triphosphate (ATP) counts on high-touch surfaces were measured pre- and post-disinfection.
Main Results:
- UV disinfection significantly decreased ATP counts on high-touch surfaces.
- Post-disinfection surface cultures showed a reduction in bacterial presence (from 33% to 4.4%).
- Significant decreases were observed in overall nursing home-acquired infections, urinary tract infections, respiratory infections, and skin/soft tissue infections.
- Infection-related hospitalizations, including pneumonia, significantly decreased.
Conclusions:
- Pulsed-xenon UV disinfection is more effective than manual cleaning alone in reducing surface microbes.
- UV disinfection demonstrably lowers infection rates and hospitalizations in long-term care facilities.
- Increased emphasis on environmental surface disinfection in long-term care settings may reduce facility-acquired infections.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Hand hygiene
Hand washing...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Antimicrobial Effectiveness
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...

