Related Experiment Video
Updated: Mar 6, 2026

Enhancing Electrode Location Assessment in Cochlear Implantation via Computed Tomography Image Fusion
Published on: January 17, 2025
Improving the accuracy of microelectrode recording in deep brain stimulation surgery with intraoperative CT
Ryan B Kochanski1, Gian Pal2, Sander Bus2
1Department of Neurosurgery, Rush University Medical Center, 1725 W. Harrison Street, Suite 855, Chicago, IL 60612, United States.
Abstract:
Microelectrode recording (MER) is used to confirm electrophysiological signals within intended anatomic targets during deep brain stimulation (DBS) surgery. We describe a novel technique called intraoperative CT-guided extrapolation (iCTE) to predict the intended microelectrode trajectory and, if necessary, make corrections in real-time before dural opening. Prior to dural opening, a guide tube was inserted through the headstage and rested on dura. Intraoperative CT (iCT) was obtained, and a trajectory was extrapolated along the path of the guide tube to target depth using targeting software. The coordinates were recorded and compared to initial plan coordinates. If needed, adjustments were made using the headstage to correct for error. The guide tube was then inserted and MER ensued. At target, iCT was performed and microelectrode tip coordinates were compared with planned/adjusted track coordinates. Radial error between MER track and planned/adjusted track was calculated. For comparison, MER track error prior to the iCTE technique was assessed retrospectively in patients who underwent MER using iCT, whereby iCT was performed following completion of the first MER track. Forty-seven MER tracks were analyzed prior to iCTE (pre-iCTE), and 90 tracks were performed using the iCTE technique. There was no difference between radial error of pre-iCTE MER track and planned trajectory (2.1±0.12mm) compared to iCTE predicted trajectory and planned trajectory (1.76±0.13mm, p>0.05). iCTE was used to make trajectory adjustments which reduced radial error between the newly corrected and final microelectrode tip coordinates to 0.84±0.08mm (p<0.001). Inter-rater reliability was also tested using a second blinded measurement reviewer which showed no difference between predicted and planned MER track error (p=0.53). iCTE can predict and reduce trajectory error for microelectrode placement compared with the traditional use of iCT post MER.
More Related Videos
09:36In vivo Positron Emission Tomography to Reveal Activity Patterns Induced by Deep Brain Stimulation in Rats
Published on: March 23, 2022
09:00Investigating the Function of Deep Cortical and Subcortical Structures Using Stereotactic Electroencephalography: Lessons from the Anterior Cingulate Cortex
Published on: April 15, 2015