Electrical Cardiometry: A Reliable Solution to Cardiac Output Estimation in Children With Structural Heart Disease
Jitin Narula1, Sandeep Chauhan1, Sivasubramanian Ramakrishnan2
1Department of Cardiac Anesthesiology, Cardio and Neuro Sciences Centre, All India Institute of Medical Sciences, New Delhi, India.
Objective:
Comparison of cardiac output (CO) obtained using electric cardiometry (EC) and pulmonary artery catheterization (PAC) in pediatric patients with congenital structural heart disease.
Design:
Prospective, observational study.
Setting:
A tertiary hospital.
Participants:
The study comprised 50 patients scheduled to undergo cardiac catheterization.
Interventions:
CO data triplets were obtained simultaneously from the cardiometry device ICON (Osypka Medical, Berlin, Germany) and PAC at the following predefined time points-(1) T1: 5 minutes after arterial and venous cannulation and (2) T2: 5 minutes postprocedure; the average of the 3 readings was calculated. Reliability analysis and Bland-Altman analysis were performed to determine the limits of agreement, mean bias, and accuracy of the CO measured with EC.
Measurements And Main Results:
The measured EC-cardiac index 4.22 (3.84-4.60) L/min/m2 and PAC-cardiac index 4.26 (3.67-4.67) L/min/m2 were statistically insignificant (p value>0.05) at T1. Bland-Altman analysis revealed a mean bias of 0.0051 L/min/m2 and precision limits of±0.4927 L/min/m2. The intraclass correlation coefficient was 0.789 and Cronbach's alpha was 0.652, indicating good reproducibility and internal consistency between the two techniques. Postcatheterization analysis also revealed strong agreement and reliability between the two techniques.
Conclusions:
This study demonstrated that cardiac indices measured in children with a variety of structural heart diseases using EC reliably represent absolute values obtained using PAC. EC technology is simple and easy to use and offers noninvasive beat-to-beat tracking of CO and other hemodynamic parameters in children with structurally abnormal hearts.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...