Field-Free Atmospheric Pressure Photoionization-Liquid Chromatography-Mass Spectrometry for the Analysis of Steroids
Ross D McCulloch1, Damon B Robb1
1University of British Columbia , Department of Earth and Ocean Sciences, 2049-2207 Main Mall, Vancouver, British Columbia V6T 1Z4, Canada.
Abstract:
A comparison study is presented in which the relative performance of a new orthogonal geometry field-free atmospheric pressure photoionization (FF-APPI) source was evaluated against both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) for the analysis of a small panel of clinically relevant steroids, spiked within various complex biological matrices. Critical performance factors like sensitivity and susceptibility to matrix effects were assessed using a simple, isocratic, high-throughput LC-MS workflow. FF-APPI was found to provide the best performance in terms of both sensitivity and detection limit for all of the steroids included in the survey. Order-of-magnitude sensitivity advantages were realized for some low polarity analytes including both estradiol and estrone. A robust linear regression, post extraction addition method was used to evaluate the relative impact of matrix effects upon each ionization method using protein precipitated human serum, plasma and Surine (simulated urine) as standard clinical matrices. Under conditions optimized for sensitivity, both the field-free APPI and APCI sources were found to provide similarly high resistance to matrix suppression effects, while ESI performance was impacted the most dramatically. For the prototype FF-APPI source, a strong relationship was established between optimizable source parameters and the degree of ion suppression observed. Through careful optimization of vaporization temperature and nebulizer gas pressure it was possible to significantly reduce or even eliminate the impact of matrix effects, even for high-throughput LC-MS methods.
More Related Videos
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
11:17A Simple Fractionated Extraction Method for the Comprehensive Analysis of Metabolites, Lipids, and Proteins from a Single Sample
Published on: June 1, 2017
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
MALDI-TOF Mass Spectrometry
High-Performance Liquid Chromatography: Instrumentation