Related Experiment Video
Updated: Mar 6, 2026

Simulator Training for Endovascular Neurosurgery
Published on: May 6, 2020
Validation of a difficult endotracheal intubation simulator designed for use in anaesthesia training
S Brettig1, M Shurgott2, S J Quinn3
1GP Registrar, Ovens Medical Group, Wangaratta, Victoria.
Abstract:
There is a need for a validated endotracheal intubation trainer that has variable difficulty settings for the training and assessment of medical practitioners. In this study three anatomical modifications were retrofitted to a commercial manikin and then validated. These modifications included restricted movements of the mandible as well as changes to the upper incisors. A total of 130 participants comprising specialists, trainees and medical students volunteered for this study. Validity was tested using randomised between-groups comparison of the time taken to intubate the manikin on all settings. Overall, and at each setting, there was a significant difference between the times to intubation among the three levels of experience (P <0.001). Novices were more than 12 times more likely to fail than experts (odds ratio [OR] 12.4, 95% confidence intervals [CI] 3.8, 41.8, P <0.001). The median time to intubation for all three groups changed significantly between settings 1 (easiest) and 4 (most difficult), novice 18 seconds (CI 8.9, 27.1, P <0.001), intermediate 15 seconds (CI 6.5, 23.5, P=0.001), and expert 9 seconds (CI 0.4, 17.6, P=0.04). The novice group was significantly different from the expert group at all attempts (P <0.002), and from the intermediates at all attempts apart from the third (P=0.055). The time for the novice and intermediate groups improved significantly by the fourth attempt, novice 15 seconds (CI 5.4, 24.6, P=0.002) and intermediate 10 seconds (CI 1.0, 19.0, P=0.03). Other aspects of validity were also satisfied during this study. A high degree of validity was established for these modifications, which can be retrofitted to an existing manikin and then used for teaching or assessment.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...

