Low-power operation of a barometric pressure sensor for use in an automatic fall detector
Abstract:
The use of a barometric pressure sensor in a wearable fall detector has been shown to improve the detection accuracy by determining the altitude change associated with the fall event. However, the barometer is a high-power-consuming sensor. This paper proposes a fall detection approach using a hermetically sealed and waterproof enclosure incorporating a small window covered by a semi-permeable membrane (SPM) to delay the equilibrium of internal and external pressures. This feature can be utilized to limit the time the barometer is powered but still capturing critical pressure information to discriminate fall and non-fall events. The proposed fall detection system is evaluated with an existing data set of simulated fall and activities of daily living in which the barometric pressure data are delayed using a mathematical model of the enclosure and SPM assembly. Also, a benchtop test is performed to estimate the power and battery life. The proposed fall detection system achieves 94.0% sensitivity and 90.0% specificity with an estimated battery life of 995.7 days.
More Related Videos
11:26Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
10:28Sensitivity Enhancement of Soft Capacitive Pressure Sensors Using a Solvent Evaporation-Based Porosity Control Technique
Published on: March 24, 2023
Related Concept Videos
Application of Linearization and Approximation
Measurement of Blood Pressure
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pressure Gauges