Photoplethysmography derivatives and pulse transit time in overnight blood pressure monitoring
Abstract:
Overnight continuous blood pressure measurement provides simultaneous monitoring of blood pressure and sleep architecture. By this means, we are able to investigate whether different sleep events are associated to blood pressure fluctuations. In this paper, we used the Pulse Transit Time (PTT) to develop and evaluate functions for measurement of blood pressure. We focused on the first and second derivatives of fingertip Photoplethysmography (PPG) recordings to detect PPG critical points. By applying R wave of ECG and PPG critical points, we created two PTT-based models for estimation of systolic and diastolic blood pressure (SBP and DBP). Seven subjects polysomnography datasets that contained PPG, ECG and blood pressure recordings were utilised to validate and compare developed PTT-BP functions. Results found that if the peak of the first derivative of PPG (VPG) was considered as the pulse pressure arrival point, the resulted PTT (PTTV) would more accurately predict both SBP and DBP. The average R-squared coefficient for SBP and DBP were correspondingly 0.593 and 0.416. The obtained mean error for PTTV based functions in SBP was ±3.96 mmHg with standard deviation of 1.41 mmHg and in DBP was ±6.88 mmHg with standard deviation of 3.03 mmHg. We concluded PTT detected from VPG is a reliable and suitable maker for overnight continuous blood pressure monitoring.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse
The pulse serves as a clinical...
Special considerations while measuring pulse