Noninvasive and continuous blood pressure measurement via superficial temporal artery tonometry
Abstract:
The measurement of blood pressure is an important cardiovascular health assessment, yet the current set of methodologies is limited in resolution, repeatability, accuracy, simplicity, and safety. This paper presents the design and prototype implementation of a novel and easy-to-use medical device for noninvasive and continuous blood pressure monitoring through tonometry at the superficial temporal artery (STA). The device features a stable form factor inspired by over-ear headphones that adjusts easily from person to person using a combination prismatic and rotational joint. A stepper motor and pressure sensor, built into the device, apply a controlled force to flatten the artery and measure the wearer's blood pressure. The design is fully wireless, using Bluetooth communication to connect to a custom control and monitoring interface on the user's laptop that allows for easy calibration and real-time measurement. Preliminary testing of the device showed a percentage error from a blood pressure cuff mean arterial pressure measurement of 7.7% (7.0 mmHg). This was also compared to a Nexfin vascular unloading device, which showed a percentage error from the blood pressure cuff of 7.3% (6.6 mmHg).
More Related Videos
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...